Operation; Control Panel Operation; Control Knob; Programming - Chauvet Professional Net-X II Manual De Usuario

Ocultar thumbs Ver también para Net-X II:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation

4. Operation

Control Panel Operation

The Net-X II is configured through the control panel, using the control panel buttons. Once the Net-X II is
properly configured it operates without user intervention.
The Net-X II can be used as a DMX splitter, in which case the DMX In ports must be assigned to the DMX
Out ports, but the Net, Subnet, and IP address settings may not need configuration.
The Net-X II can be used as an Art-Net™ node, in which case the Art-Net™ universes must be assigned to
the DMX Out ports, and the Net, Subnet, and IP address settings must be configured.
The Net-X II can be used as an sACN node, in which case the sACN universes must be assigned to the
DMX Out ports, and the IP address settings must be configured.
The Net-X II can be used as both a DMX splitter and either an Art-Net™ or sACN node simultaneously, in
which case both the DMX assignments and the Art-Net™ or sACN settings must be configured. For more
information, see Example Configurations.
The Net-X II can be used to merge two DMX, Art-Net™, or sACN signals from different controllers and
output as one signal, using LTP (Latest Takes Precedence) and HTP (Highest Takes Precedence)
functions.
The Net-X II has backup settings and configurations with same or other Net-X IIs.
The Net-X II is webserver supported for remote configuration and backup/update.
The Net-X II's record function allows you to record looks from a controller and save them into memory

Control Knob

The Net-X II has a knob that is used to scroll through the options in the menu. Press the knob to make a
selection.

Programming

Refer to the Menu Map to understand the menu options. The menu map shows the main level and a
variable number of programming levels for each option.
To access the menu from the Home Screen, press the knob.
To scroll through the options on each level of the menu, turn the knob. Turn it clockwise to scroll
down, and turn it counter-clockwise to scroll up.
Press the knob to select the highlighted option. This will take you to the next programming level for
that option, or it will highlight a value that can be edited.
To increase a selected number value, turn the knob clockwise. To decrease a selected number
value, turn the knob counter-clockwise.
Press Exit/Cancel to the previous main level.

Menu Map

M
L
AIN
EVEL
Custom Device
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Name
Set IP Mode
Manual IP
Set Netmask
Operating Mode
Net-X II User Manual Rev. 2
P
L
ROGRAMMING
Static IP
___ ___ ___ ___
___ ___ ___ ___
Exit
A. 255.000.000.000
B. 255.255.000.000
C. 255.255.255.000
Exit
8 Port
2 + 8 Port
Exit
D
EVELS
ESCRIPTION
Cancel
Inputs a custom device name
Enter
Default address-cannot be changed
Cancel
Sets the IP Addresses
Enter
Exits to previous screen
Sets Netmask A
Sets Netmask B
Sets Netmask C
Exits to previous screen
Assigns each port as an output/
input (this also supports RDM over
Ethernet)
Supports DMX merging with the two
DMX inputs
Exits to previous screen
8

Publicidad

Tabla de contenido
loading

Tabla de contenido