THERMOBILE Bio Energy 2 Manual Del Usuario página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
English
Fault
The flame extin-
guishes immediately
after ignition; the
control light is on.
The air combustion
fan keeps running,
while the hot air fan
has stopped and the
heater has cooled
down.
There is soot forma-
tion in the combus-
tion chamber and in
the flue.
There is soot forma-
tion in the combus-
tion chamber and in
the flue.
There is leakage
between the bottom
of the control panel
and the vaporiser.
26
Cause
7
There is water or sedi-
ment in the fuel tank.
8
The fuel supply pipe is
blocked: The fuel flows
back into the fuel tank
through the return pipe.
9
There is no proper flue
draught.
10 The combustion thermo-
stat is defective.
11
The combustion air fan
does not work.
12 There is insufficient sup-
ply of combustion air.
13 The flue draught is too
high or irregular.
14 There is leakage
between the bottom of
the control panel and
the vaporiser.
40.020.953 - rev. 05 - 2015
Solution
Clean the fuel tank and the
fuel filter, see fig. 3.
Clean the fuel supply pipe or
replace if necessary.
Check whether the flue is fit-
ted according to the instruc-
tions, see "flue".
Check the flue for leakage.
Clean the flue if necessary.
See faults: 3 and 4.
Replace the combustion
thermostat.
Check the motor and replace
if necessary.
Clean the holes in the vapor-
iser.
Check the operation of the
combustion air fan.
Position a flue stack valve,
see "flue".
Adjust the flue to the correct
pressure, see § 5.3.
See faults: 9, 12 and 13..
Adjust the pressure on the
seal cord.
Replace the seal cord.
Action
User
User
User
User
User
User
Dealer
User
User
Dealer
User
User
Bio Energy series

Publicidad

Tabla de contenido
loading

Productos relacionados para THERMOBILE Bio Energy 2

Tabla de contenido