7
12. Make sure refill tube adaptor (I) is attached
to the top of the flush valve overflow tube. Note:
Flow from the refill tube must be positioned di-
rectly over the overflow tube.
13. IMPORTANT: Always clear sand and rust
from system.
• Remove valve top by lifting arm and rotat-
ing top 1/8 turn counterclockwise.
• While holding a container over the un-
capped valve to prevent splashing, turn
water supply on and off a few times. Leave
water supply off.
• Replace top by engaging lugs and rotating
1/8 turn clockwise. Make certain top is
turned to the locked position. Valve may
not turn on if the top is not fully turned
to the locked position.
14. Turn on water supply to the toilet and check
for leakage. Inspect connection points of the wa-
ter supply line to the toilet tank fill valve, water
supply line to water supply valve, the bottom of
the toilet tank mounting area, and around the
base of the toilet bowl (A). Carefully tighten any
connections that are leaking.
15. Adjust water level in toilet tank (B) to marked
water line. Turn the water level adjustment screw
(J) to move the float cup (K) up or down.
16. Check action and nut tightness (left hand
thread) of toilet tank lever (L). Also, check loose-
ness of flapper chain (there should be slight slack
in chain when at rest) and seal of flush valve flap-
per.
17. Carefully place the toilet tank cover (M) onto
the top of the toilet tank (B).
18. Install toilet seat (N) per manufacturer's in-
structions.
Please refer to Homeowner Care Manual for troubleshooting, care and mainte-
nance information.
8