Descargar Imprimir esta página

3B SCIENTIFIC 1012850 Instrucciones De Uso página 6

Paquete-sw

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Dynamic force sensor set-up
The sensors are optimally designed to be mounted on
stands assembled from the SW stand equipment set
(1012849). (See instructions for pendulums listed
below.)
In addition, they can be mounted on plates or on
any rods of 10-mm diameter by means of their
knurled screw.
Caution: Dynamic force sensors must not be
subjected to mechanical overloading
Neither sensor hook may be loaded with
more than 5N in the axial direction and 1 N
in transverse direction.
Be especially careful with the maximum
loading force when assembling the system
or suspending loops or springs from the
hook.
2.2 MEC electronics board
1a
f
1b
Fig. 1
MEC electronics board
1a Connector for plug-in mains supply
1b A and B inputs for dynamic force sensors
1c A and B outputs for dynamic force sensors
1d
output for phase detector
ΔφAB
Amplifier channels
Amplifier channels A and B on the MEC elec-
tronics board are used in conjunction with the
dynamic force sensors. The board converts the
signals from both sensors to make them suitable
for display in an oscilloscope or other display
instrument. The two channels have high internal
12V AC
M
A
B
C
Δ ϕ
A B
resistance. In addition, the phase difference
between the two signals can also be evaluated
and output. The other inputs on the board are
not used for this purpose.
Phase detector
A phase detector compares the waveforms for
channels A and B in the time domain to deter-
mine the difference in phase between them.
Output
supplies the actual phase differ-ence
ΔφAB
in the form of a DC voltage between 8 V (∆φ
ΔφAB
= 0°) and +8 V (∆φ = 180°).
2 Dynamic force sensors
2 HF cables
1 MEC electronics board
1 Plug-in power supply, 12 V AC
Dynamic force sensor
Maximum force
Axial plane:
Radial plane:
Lower frequency limit: 0.2 Hz
Connector:
Length of cable
1c
Dimensions:
Weight:
Electronic board
Power supplied via plug-in mains transformer
Input sockets:
Output sockets:
1d
Amplifier A, B:
Phase detector (XOR): Output ±8 V,
Dimensions:
Plug-in power supply for 1012850
Primary side:
Secondary side:
Plug-in power supply for 1012851
Primary side:
Secondary side:
Only power the MEC electronics board from the
supplied 12 V AC mains transformer.
2
3. Contents
4. Technical data
5 N
1 N
3.5-mm jack plug
0.8 m
52 x 37 x 26 mm approx.
80 g approx.
3.5-mm jack sockets
BNC
Output ±8 V,
Ri = 100 MΩ
Ra = 1 kΩ
Ra = 1 kΩ
65 x 100 x 40 mm approx.
230 V, 50/60 Hz
12 V AC; 700 mA
115 V, 50/60 Hz
12 V AC; 500 mA

Publicidad

loading

Este manual también es adecuado para:

1012851