SE288 TWO-IN-ONE 8MM Punch/Flange Tool
OPERATION...
PUNCHING:
1. WARNING: Always wear heavy-duty leather gloves when
handling sheet metal. Sharp edges can cause severe injury.
Always wear ANSI-approved safety goggles.
2. Pre-mark the desired location of each hole you wish to
punch on the workpiece.
NOTE: If the workpiece is to be both punched and flanged,
flange it first, then measure for the hole placement. Flanging will
change the dimensions of the workpiece.
3. Connect the Punch/Flange Tool to your air supply. Do not
exceed 90 PSI.
4. Insert the edge of the workpiece between the Punch Die (36)
and the Punch (32). Make sure your marks are aligned with
the Punch Die (36).
5. Squeeze the Throttle Lever (30), and the Punch (32) will
pierce the workpiece.
6. Align the tool with the next mark on the workpiece, and
repeat step 5 until the job is finished.
7. Disconnect the air supply.
8. WARNING: After disconnecting the Punch/Flange Tool
from the air supply, there could still be enough air pressure
to fire the Punch/Flange Tool. After making sure the air
supply is disconnected, ALWAYS fire the Punch/Flange
repeatedly to make sure all air is bled from the tool.
FLANGING:
1. WARNING: Always wear heavy-duty leather gloves when
handling sheet metal. Sharp edges can cause severe injury.
Always wear ANSI-approved safety goggles.
2. Measure and cut the workpiece to the correct dimensions.
3. Connect the Punch/Flange Tool to your air supply. Do not
exceed 90 PSI.
4. Secure the workpiece in a vise or use another appropriate
clamping method.
5. Insert the workpiece into the flanging jaw between the Anvil
Bed (37) and the Punch Die Bed (38). Make sure the
workpiece is all the way flush against the back of both the
Anvil Bed (37) and the Punch Die Bed (38). Squeeze the
Throttle Lever (30), and the Anvil Bed (37) will be driven
against the Punch Die Bed (38), forming a flange.
6. Release the Throttle Lever (30). Slide the tool along the edge
of the workpiece to where the Anvil Bed (37) and the Punch
Die Bed (38) overlap part of the workpiece you just flanged.
Repeat step 5.
7. Repeat steps 5 and 6 until until the entire length you wanted
to flange is finished.
8. Disconnect the air supply.
9. WARNING: After disconnecting the Punch/Flange Tool
from the air supply, there could still be enough air pressure
to fire the Punch/Flange Tool. After making sure the air
supply is disconnected, ALWAYS fire the Punch/Flange
repeatedly to make sure all air is bled from the tool.
AIR SUPPLY
Tools operate on a wide range of air pressures. It is
recommended that air pressure measures 90 psig at the tool
with the trigger fully depressed and no load applied to the tool.
Higher pressure (over 90 psig; 6.2 bar) raises performance
beyond the rated capacity of the tool, which will shorten tool life
and could cause injury.
SE288
Always use clean, dry air. Dust, corrosive fumes and/or water in
the air line will cause damage to the tool. Drain the water from
air lines and compressor prior to running tool. Clean the air inlet
filter screen weekly. The recommended hookup procedure can
be viewed in the Figure 1.
The air inlet used for connecting air supply has standard 1/4"
NPT. Line pressure should be increased to compensate for
unusually long air hoses (over 25 feet). Minimum hose diameter
should be 3/8" I.D. and fittings should have the same inside
dimensions and be tightly secured.
Always turn off the air supply, drain hose of air pressure
and detach tool from air supply before installing, removing
or adjusting any part or accessory on this tool, or before
performing any maintenance on this tool.
Ensure an accessible emergency shut off valve has been
installed in the air supply line and make others aware of its
location.
TROUBLESHOOTING
Other factors outside the tool may cause loss of power or erratic
action. Reduced compressor output, excessive drain on the air line,
moisture or restrictions in air pipes or the use of hose connections
of improper size or poor conditions may reduce air supply. Grit or
gum deposits in the tool may cut power and may be corrected by
cleaning the air strainer and flushing out the tool with gum solvent oil
or an equal mixture of SAE #10 and kerosene. If outside conditions
are in order, disconnect tool from hose and take tool to your nearest
authorized service center.
LUBRICATION AND MAINTENANCE
Lubricate the air motor daily with high quality air tool oil. If no air
line oiler is used, run 1/2 oz. of oil through the tool. The oil can
be squirted into the tool air inlet or into the hose at the nearest
connection to the air supply, then run the tool. A rust inhibitive
oil is acceptable for air tools.
WARNING: After an air tool has been lubricated, oil will
discharge through the exhaust port during the first few seconds
of operation. The exhaust port must be covered with a towel
before applying air pressure to prevent serious injury.
INSPECTION, MAINTENANCE AND
CLEANING
1. BEFORE EACH USE, inspect the general condition of the
tool. Check for loose screws, misalignment or binding of
moving parts, cracked or broken parts, and any other
condition that may affect its safe operation. If abnormal
noise or vibration occurs, have the problem corrected before
further use. Do not use damaged equipment.
2. WHEN NECESSARY, fill the hydraulic system with a high
quality hydraulic oil. Remove the Oil Plug (7), refill and then
replace the Oil Plug (7).
3. To adjust the Punch, loosen the Set Screw (40), and rotate
the tool head. After making needed adjustment, tighten the
Set Screw (40).
3