Installation notes
EN
3
Installation notes
Take note of all safety and warning information in
X
X
these operating and installation instructions, as well
as those for BORA cooktop extractor PL540E and the
BORA cooktop extractor system CKASE (see the
Safety chapter).
3.1
Checking the scope of delivery
Name
ULS25 plinth fan
Installation notes
Sealing tape – plinth fan
Tab. 3.1: Scope of delivery
Check the scope of delivery for damage and make
X
X
sure it is complete.
If there are any missing or damaged parts, please
X
X
notify BORA After Sales Service.
Do not under any circumstances install parts which
X
X
are damaged.
Dispose of transport packaging in the proper manner
X
X
(see the Decommissioning and Disposal chapter).
3.2
Installing the plinth fan
INFO
The floor unit must not be supported on the
plinth fan housing.
Prepare the fan by attaching the sealing tape
X
X
depending on the installation situation
(see Installation chapter, PL540E/CKASE).
The plinth fan can be installed freestanding or suspended.
3.2.1 Freestanding installation
Clean any major dirt from the supporting surface.
X
X
Position the plinth fan in the intended installation
X
X
position.
Ensure that the plinth fan is securely positioned on all
X
X
4 feet.
Make sure that the connection cables are accessible.
X
X
3.2.2 Removing the inlet nozzle for
installation purposes
You can remove the plinth fan's inlet nozzle from the fan
housing for installation purposes.
8
Fig. 3.1 Removing the inlet nozzle
Quantity
1
Unlock the inlet nozzle by turning it to the left.
X
X
Lift the inlet nozzle up off the fan housing.
1
X
X
Position the plinth fan in the installation position.
X
X
1
Place the inlet nozzle on the fan housing.
X
X
Lock the inlet nozzle by turning it to the right.
X
X
The end positions when unlocking and locking the inlet
Q
Q
nozzle are specified by an end stop.
3.2.3 Suspended installation
If the plinth fan is installed suspended, the fixing
Q
Q
material must be made available at the installation
site in accordance with the building material.
The maximum tightening torque of the fixing nut is
Q
Q
10 Nm.
Secure the plinth fan to the three mounting straps
X
X
prepared on the housing.
The connection cables must be secured with the cable
X
X
routing clip provided.
3.3
Connecting the plinth fan to the
universal control unit
Fig. 3.2 Connection plug of the plinth fan
[1]
Plinth fan connection plug control line
[2]
Plinth fan connection plug power supply cable
Connect the fan's control line [1] to the universal
X
X
control unit [4].
Connect the fan's power supply cable [2] to the
X
X
universal control unit [6].
Check the plug connections to ensure that they are
X
X
secure.
Make sure that the cable is not damaged.
X
X
Verify that the installation was done correctly.
X
X
1
2
www.bora.com