Fault
The appliance turns
Appliance is overloaded
on, but the
temperature is too
high/low
The appliance is
The appliance is not properly
leaking water
levelled
The discharge outlet is blocked
Movement of water to the drain
is obstructed
The water container is
damaged
The appliance is
The frame has become loose
unusually loud
The appliance has not been
installed in a level or stable
position
Electrical Wiring
POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as
standard.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
•
Live wire (coloured brown) to terminal marked L
•
Neutral wire (coloured blue) to terminal marked N
•
Earth wire (coloured green/yellow) to terminal marked E
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
Technical Specifications
Model
Voltage
Power
G619
230V
130W
G211
50Hz
CB507
230V
130W
DP288
50Hz
CB509
230V
250W
DP289
50Hz
CG582
230V
210W
50Hz
5
Probable Cause
Temperature
Current
Range
0.9A
2°C to 12°C
0.9A
2°C to 12°C
1.5A
2°C to 12°C
1.35A
2°C to 12°C
Reduce the amount of food stored in the appliance
Adjust the screw feet to level the appliance (if applicable)
Clear the discharge outlet
Clear the floor of the appliance (if applicable)
Call POLAR agent or qualified Technician
Check and tighten all nuts and screws
Check installation position and change if necessary
Capacity
Refrigerant
(litres)
70
R134a 70g
86
R134a 83g
235
R134a 180g
100
R600a 50g
Action
Dimensions
H x W x D (mm)
885 x 428 x 386
980 x 428 x 429
1695 x 515 x 485
1100 x 565 x 565
Weight
(kg)
32.5
36,5
76.4
50