Aculux 4" FMA5-SC Flush Mount Adapter for wood, stone, tile,
and other solid ceilings
These adapters are for use only with Aculux 4" round aperture fixtures using flush-mount trims.
FMA5-SC087 is for use with 1/2" thick to 7/8" thick ceilings.
FMA5-SC125 is for use with 7/8" thick to 1-1/4" thick ceilings.
FMA5-SC163 is for use with 1-1/4" thick to 1-5/8" thick ceilings.
Note: Aculux thick ceiling adapters are not required when using FMA5-SC adapters.
Note: Aculux housings require vertical adjustment of the aiming mechanism to ensure maximum performance at various ceiling
thicknesses. The aiming mechanism can be set for 1/2" thru 1-1/2" ceiling thicknesses with 1/8" increments before or after housing
installation. This adjustment must be set for proper retention of the trims.
To adjust (refer to Fig. 1):
1. Loosen thumb nuts (A) on both sides of the aiming mechanism.
2. Flex left and right trim retainer/height adjustment brackets (B)
inward to disengage aiming mechanism.
3. Raise or lower aiming mechanism until indicators point to the
corresponding ceiling thickness (C). If ceiling thickness is
unknown, measure from housing to ceiling surface (D) and
subtract 1/8" from this measurement. Set aiming mechanism
height at this value.
4. Allow trim retainer/height adjustment brackets to flex back
towards original position, locking height.
5. Tighten thumb nuts loosened in step 1.
Trim Spring Height Adjustment
In some applications, trim spring height adjustment is required.
If ceiling thickness is 1-5/8" to 1-3/4", one spacer per trim spring
is required. If ceiling thickness is 1-3/4" to 2" two spacers per
trim spring are required. (Spacers are shipped with thick
ceiling adapters)
To install (refer to figure 2):
Remove and discard screws holding trim spring assemblies in
place. Install spacer(s) and trim spring assemblies as shown with
provided hardware.
INSTALLATION INSTRUCTIONS
Figure 1
Figure 2
©2016 Acuity Brands Lighting, Inc.
SPRING
ASSEMBLY
SPACERS
Rev 6/16
P5516