Operating Instructions
Description:
The compressed air "pneuMATO fill" filler unit is suitable for filling central lubrication systems with
commercial lubricants up to NLGI Class 2. The pump is fully automatic in operation. Opening the
isolation valve automatically starts the delivery of grease. If the valve is closed, the pump will
automatically stop the delivery of grease..
Any other use, or modification or alteration to the compressed lubricating equipment is only
permissible after discussions with the manufacturer
Putting into service and Operation:
-
Open the grease container and press the
grease follower piston firmly onto the grease..
-
Place the centralising cover onto the grease
container.
-
Loosen all 3 wing bolts and push the
centralising slides inwards (towards the centre).
-
Push the pegs to move the retainer hooks
outwards as far as they will go.
-
Now place the centralising lid onto the grease
container so that the retainer hooks are on the
outside and the centralising slides are on the
inside of the grease container.
-
Push the wing bolts to move the centralising
slides outwards as far as they will go (the lid
will automatically centralise itself on the grease
container)
-
Keeping the wing bolt pushed outwards, push
the pegs to move the retainer hooks inwards as
far as they will go. Tighten the wing bolt.
-
Secure the remaining two wing bolts and pegs
as described previously.
N.B. Check that the centralising lid is seated
firmly on the grease container.
-
The pump can now be pushed through the
clamp and locked in place with the clamping
screw.
-
Push the ZSA hydraulic coupling onto the plug
of the central lubrication unit..
-
The pneuMATO fill is now ready to use.
-
If the unit is not in use, stop the air feed to the
pump.
Comply with the safety instructions .
Section through centralising lid:
Lid size
Outside diameter of container
10 - 15
from 215 mm to 285 mm
20 - 25
from 270 mm to 340 mm
50
from 340 mm to 410 mm
Armoured rubber hose
Air
connection
Retainer hook with peg
Lock nut
Centralising slide
with wing bolt
Ø for grease container
/ English
ZSA hydraulic
coupling
Accessory
Grease
outlet
Clamping bolt
Centralising slide
with wing bolt
Retainer hook
with peg
Centralising lid
cpl. When ordering
give outside
diameter of tub
Grease follower
piston.
When ordering
give inside
diameter of tub
Grease container
7