Installation
Installation kit
4 x Self-tapping screws Ø6,5 x 38
4 x Metal washers Ø22 x 10 x 1,6
4 x Nylon bushings
1 x Power cable
1 x Hexagonal safety key
1.
Make sure power supply breaker is switched off. Installation must be carried out in accordance with the current edition of the
local wiring regulations code having jurisdiction. Installation should be performed only by a qualified electrician.
2.
Place template against wall at desired height (see mounting height recommendations) and mark locations of 4 mounting holes
and wire service entry at knockout location.
3.
Remove and retain 2 cover screws and cover.
4.
a. For in-wall (concealed) power supply - Provide supply wire to knockout location according to local code and attach securely
to chassis at knockout with appropriate strain relief connector (not supplied).
6.
b. For Surface Mounted Conduit power supply - Provide appropriate conduit to entry location according to local code and
attach securely to chassis with correct strain relief connector (not supplied).
7.
Drill 4 holes at locations A, B, C and D of Ø8 Diameter x 35mm deep if using wall anchors supplied with unit. Install supplied
anchors flush with wall face, or install other fastening system suitable for wall conditions (not supplied). Attach dryer to wall.
For wood wall/studs use M6 screws at length that will ensure 25 mm min. stud penetration. For masonry walls use expansion
bolts or anchors for M6 screws to ensure penetration 6 mm deeper than anchor. Shim if necessary to ensure base plate is flat
against wall.
7.
Connect supply and ground wires to terminal block where indicated or connect supply wires to terminal block where indicated
and connect ground wire to base plate with ground screw.
D. Connect the live wire (colored Brown, Red or Black) to the terminal block marked "L"
E. Connect the neutral wire (colored Black, Blue, White or Grey) or connect the second live wire (colored Red or Orange) to the
terminal block marked "N"
F. Connect the ground wire to the terminal block marked " " or to the green screw marked " ". Bare grounding (earth) wires
should be sleeved with green and yellow or green tubing. Colors of live and neutral wires depend on voltage of supply service
and requirements of Building and Electrical Code having jurisdiction.
8.
Replace cover. Do not over-tighten screws.
Cleaning
Periodic cleaning of the unit is recommended to ensure optimal performance.
Disconnect the electrical supply.
Remove the two cover-mounting screws.
Remove the cover.
Clean all dust lint from the interior of the dryer.
Wipe the cover with a damp cloth and mild cleaning solution. Do not Soak. Never use abrasives to clean the cover.
Replace the cover. Do not over tighten the screws.
Connections:
10