Step 6 Install stopper and set eye position
Stopper can be removable
or non-removable
determined by position
of eye hole when
inserting pivot rod.
removable
Insert
stopper
through fl ange
opening and
position eye hole.
When installed in removable position,
Removing stopper
move pivot rod to the up position (lift rod is in the down position
when later installed). Eye hole will slide over end of pivot rod.
Step 7 Attach pivot rod to drain body
Remove
retaining nut
and outer seat from
pivot cavity.
Insert
pivot rod
into pivot cavity so
ball is against inner
seat and end of rod
passes under stopper
according to selected
eye hole position.
Slide
outer seat over
pivot rod with curved end against pivot ball.
Fasten
pivot rod to drain body with retaining nut.
Tighten using your fi ngers until ball is seated snug
and pivot rod can move around freely.
Step 8 Connect lift rod and adjust linkage
Insert
lift rod
through hole on
top of water spout.
Fasten end of
pivot
rod with spring clip
through location
hole in clevis strap
that is best aligned
to enable lift rod
also fasten to end
of clevis strap when
in the up position
and stopper is in the
closed position.
Insert
lift rod into
end of clevis strap
and fasten with
thumb screw at
location where
stopper can be easily opened and closed.
If necessary, select another location hole in clevis
strap and re-adjust lift rod where fastened to clevis strap.
Step 9 Attach drain body to drain trap
stopper
flange
non
removable
pivot rod
retaining nut
outer seat
pivot ball
inner seat
pivot cavity
clevis strap
pivot rod
Step 10 Flush water supply lines
Th oroughly fl ush supply
lines to prevent foreign
matter, i.e. copper chips,
sand, etc. from damaging
the sealing surface inside
control valves.
Remove aerator from
end of faucet spout
by rotating counter
clockwise
Turn hot and cold faucet
handles to full ON position and then open
water sup ply valves to fl ush supply lines thor ough ly.
Turn faucet
Care of faucet fi nish
Clean fi nish area by using mild soap and water or non-abrasive
cleaner and then rinse immediately. A non-abrasive wax may
be used to preserve fi nish area.
Valve cartridge replacement
Step 1 Remove handle
Carefully pry loose button plug
and remove Phillips head screw.
Step 2 Remove collar
Remove collar by turning counter
clockwise.
Ensure not to use any tool
Note:
that could scratch fi nish without
taking protective measures.
Step 3 Remove cartridge
lift rod
Using a wrench, turn hex nut
on cartridge counter clockwise.
Ensure valve assembly under
Note:
sink doesn't rotate
while turning nut.
thumb
Step 4 Insert cartridge
screw
Insert replacement cartridge and
location
tighten hex nut using a wrench.
holes
spring
Step 5 Attach collar
clip
Screw collar onto fastener and tighten using your hand.
Step 6 Attach faucet handle
Ensure cartridge spindle is
rotated to the
Attach handle to top of spindle
in
location as shown.
OFF
Fasten with screw and replace
button plug.
Page 3
Page 3
remove
aerator
, replace aerator and check for any leaks.
OFF
plug button
screw
handle
spindle
hot = cw
cold = ccw
cartridge
fastener
position.
OFF
collar
OFF
handles set in
the OFF position

Publicidad