quick start guide can be used to aid the setup of your welder but it's important to fully read and
understand this manual fully prior to setting up the welding machine.
1. Ensure that the air intake of the machine is not blocked or covered.
2. Attach the gas supply and ensure that every part of the gas supply is tightly connected. Poor
connections will allow gas to escape / air could get into the system. Use a regulating valve.
3. Ground the unit by using the ground connecting screw at the back of the machine and connect to a
grounded metal point free from the weld surface.
4. MMA welding - ensure that the cable of the Electrode Holder is securely attached to the negative (-)
terminal and fasten clockwise.
5. ARC welding - insert the plug of the TIG welding gun into the connector in the front panel and fasten
clockwise. Connect the HF Plug on the gun to the connector on the front panel.
6. Connect the earth cable to the connector on the front panel.