RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS
Our appliances are tested and regulated with liquid gas (see data plate).
The conversion or adaptation to another type of gas must be carried out by a specialized technician. The nozzles for the
various types of gas are supplied in a packet and are marked in hundredths of mm (see "burners" technical data table).
SUBSTITUTING THE NOZZLE IN THE MAIN BURNER
Remove the grills, the burners and the containers, with a suitable spanner substitute the nozzles (5) with the right ones,
regulate the primary air (h) (see "burners" technical data table) by unscrewing the fixing screws and relative jam nut.
After having carried out the regulation, screw back the screw and the jam nut, regulate minimum output by turning the
screw to the right or to the left until thermal output reaches 1.2 kW for the burner of 3.5 kW, and 1.8 for the burner of
5.5 kW.
WARNING: For functioning with liquid gas, the regulation screw (8) for minimum output must be completely
blocked.
•
The instructions necessary for use are enclosed with the appliance.
•
Check the appliances for gas leaks.
•
Check the lighting and flame of the main burner.
•
We urge the user to follow the instructions when using the appliance.
With prolonged use of the appliance, it is essential to carry out regular maintenance for the safe functioning of the
appliance; we therefore recommend drawing up a contract for after sales service.
Maintenance must be done only by specialized personnel, observing the norms in force and our indications.
OPEN COOKING RINGS :
Attention! Use the appliance only under surveillance.
LIGHTING AND REGULATING OPEN COOKING RINGS
On the front panel, above each knob, there is a symbol which indicates to which burner the knob
corresponds.
To light, turn the knob to the left from position "0" to the
down and press the button with the
The knob must be kept pushed down for a few seconds and then released . The flame may go out,
in which case it is necessary to repeat the procedure. By turning to the
brought to the minimum. To put out the burner, turn the knob back into the "0" position.
GB
CHECKING FUNCTIONING
MAINTENANCE
SPARE PARTS
it is possible to substitute the gas-cocks and the central lighting unit by removing the
front panel and to substitute the spark plugs, thermocouple and burners by removing
the grills and the containers.
INSTRUCTIONS FOR USE
symbol until the gas lights.
24
IE
symbol (see figure); keep it pushed
position, the burner is