Unscrew and temporarily remove the protection cover (Picture 26).
Room thermostat is intended for wall mounting. In case you don't
have installed a flush box, tear away the drilling template from the
package and mark drilling holes. Use enclosed screws to fasten the
wall plate on the wall (Picture 27). After you have done connecting
the wires (see chapter Connecting the wires), screw back the
protection cover. Now put T1 back onto the base by doing the
following. Hook T1 on top of the wall plate and push it with bottom
towards the wall plate (Picture 17- CLOSE).
Wall
Flush box
Picture 27
Picture 26
Connecting the wires
WARNING: Mounting and wiring connections must be done by a
qualified installer or authorized company. Local regulations or VDE
0100 and EN IEC 60364 regulations for electrical installations must
be considered by doing the wiring connections.
Bring the wires through the opening in bottom of the wall plate
(Picture 27- position A). Connect wires into the terminals 1, 2 and
3. Room thermostat is capable to control the circulation pump
(Picture 28a), actuator (Picture 28b), burner (Picture 28c) or fan
(Picture 28d).
INSTALLATION MANUAL
18