COMPONENTS
Compressed Air Connection
with locking valve
Safety Valve
opens at approx. 10 – 12 bar
INSTRUCTION
1. Shut the locking and the filling valve and connect the booster to the compressed air supply.
2. Open the locking valve until the desired air pressure level is reached.
The pressure release valve opens at >10 bar.
3. Apply the filling cone with its flange to the rim.
4. Pump up the tire by opening the filling valve impulsively.
Better results can be achieved, when the tyre is filled with a tyre filler via the ordinary rim valve,
simultaneously.
APPROACH ANGLE
Choose your angle, so that the deflated air can freely float between tire and rim.
A too narrow/steep angle (onto the rim/bead) will considerably reduce the efficiency of the operation.
STORAGE AND MAINTENACE
•
Hang up the booster to the wall (using a hook).
•
Leave the filling valve open, so that possible moisture can leave the air tank.
•
Follow your national/regional safety and testing regulations.
•
Check the tank and all other mounted components for cracks and damage, regularly.
•
Never loosen or tighten any components while under pressure.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Handle
Filling Cone
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
Filling Valve
for impulsive filling
operations
Gauge
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed