CONNECTION
220 ÷ 240 V~
MOUNTING
Disconnect power supply by the phase fuse, the circuit-breaker or the switch-
disconnector combined to the proper circuit.
Check if there is no voltage on connection cables by means of a special measure
equipment.
Connect the cables with the terminals in accordance with the installing diagram.
Install RDP-01 device in installation cable box.
Switch on the power supply from the mains.
OPERATION
RDP-01 can operate in five modes:
COMFORT (Available only in cooperation with 4 push-button transmitter). In this
mode the following two functions are realised:
ONE PUSH-BUTTON Pressing the programmed push-button shortly (<0.8 sec.)
causes the dimmer to operate in the range of switch on/switch off (to the last adjust-
ment of lighting luminous density level), however pressing the programmed push-
button longer (>0.8 sec.) causes alternate lighting brightening - dimming.
TWO PUSH-BUTTONS SWITCH ON pushbutton: pressing the programmed
push-button shortly (<0.8 sec.) causes the lighting switches on according to the last
adjustment of lighting luminous density level, however pressing the programmed
push-button longer (>0.8 sec.) causes lighting brightening to the maximum level.
SWITCH OFF pushbutton: pressing the programmed push-button shortly (<0.8
sec.) causes the lighting switches off, however pressing the programmed push-
button longer (>0.8 sec.) causes lighting dimming to the minimum level.
TIME The device after pressing the pushbutton switches on according to the ad-
justed time (tp), then it switches off automatically. Another pressing of the push-
button during time countdown causes the lighting is switched off before adjusted
time finishes. Default settings - 15 seconds.
CAUTION! Adjusted time cannot be deleted.
REMOTE CONTROLS DELETION
Press PROG push-button of RDP-01 device for a longer time.
LED red diode switches on (signal pulsates) and then it switches off.
push-button in RDP-01 - MEMORY IS DELETED.
After 5 seconds
Release the