For power supply: 230V 50Hz
Power Supply
230V 50Hz
Earthing
Note:
Must be hard wired, no plug allowed.
The swimming pool heater must be earthed well.
3. Electric Wiring Diagram
Options for protecting devices and cable specification
MODEL
Rated Current A
Breaker
Rated Residual
Action Current mA
Fuse
A
Power Cord
(mm
Signal cable
(mm
※ Above data is subject to modification without notice.
Note:
The above data is adapted to power cord ≤ 10m. If power cord is>10m, wire
diameter must be increased. The signal cable can be extended to 50m at
most.
4. Installation instruction and requirement
The heat pump must be installed by a professional team. The users are not qualified
to install by themselves, otherwise the heat pump might be damaged and risky for
users' safety.
Distribution Box
(Customer prepare)
Fuse
Breaker
OKUFULL
OKUFULL
07
8.0
30
8.0
2
)
3×1.5
2
)
3×0.5
Power Cord
OKUFULL
09
13
9.5
15.0
30
30
9.5
15.0
3×1.5
3×2.5
3×0.5
3×0.5
9
Swimming Pool Heat Pump Wiring Board
OKUFULL
OKUFULL
17
21
20.5
23.5
30
30
20.5
23.5
3×4
3×6
3×0.5
3×0.5
OKUFULL
24
25.0
30
25.0
3×6
3×0.5