QuieTTest Combination
MODEL: QT100L
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at service
panel and lock service panel to prevent power from being
switched on accidentally.
When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
INSTALLATION INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards, including fire-rated
construction.
B. Sufficient air is needed for proper combustion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent back draft. Follow the heating
equipment manufacturer's guideline and safety standards such as those published by
the National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked as appropriate
for the application.
F. NEVER place a switch where it can be reached from a tub or shower.
Do not install in a ceiling insulated to a value greater than R40.
Suitable for use with solid state speed controls. Use NuTone Model VS-64.
Not for use in kitchens.
Suitable for use over a tub or shower when installed in a GFCI protected branch
circuit.
FOR BEST RESULTS
When installing the Ventilator in a new construction site, install housing during
the rough-in construction of the building. The blower unit and grille should be installed
after the finished ceiling is in place.
To install a ventilator in an existing building requires an accessible area
(attic or crawl space) above the planned location.
INSTALLATION IN A NEW CONSTRUCTION SITE
PREPARATION
1. Remove blower/power unit assembly from housing:
A. Loosen three (3) mounting screws.
B. Slide unit back to free it from mounting screws.
C. Remove unit and set aside until needed.
2. Remove one of the wiring knockouts from housing.
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
4" DIAMETER DUCT
90° ELBOW
CEILING INSTALLATION
JUNCTION BOX
ROOF CAP
WALL CAP
FIGURE 1
WHITE
WHITE
GREEN
GROUND
SCREW
EARTH
GROUND
FIGURE 2

Publicidad

loading

Resumen de contenidos para NuTone QuieTTest QT100L

  • Página 1 F. NEVER place a switch where it can be reached from a tub or shower. • Do not install in a ceiling insulated to a value greater than R40. GREEN • Suitable for use with solid state speed controls. Use NuTone Model VS-64. GROUND • Not for use in kitchens. SCREW •...
  • Página 2 MOUNTING THE HOUSING 1. Refer to Figure 3. Insert mounting brackets at each end of DISCHARGE OPENING housing. 2. Place long side of housing parallel to ceiling joist. Position housing in desired location. Make sure housing flange is even with the WIRING KNOCKOUT planned finished ceiling.
  • Página 3: Importantes Directives De Sécurité

    COUDE A 90° • Pour utilisation avec les commandes de vitesse électroniques. COUVERCLE MURAL Utiliser le modèle VS-64 de NuTone. • Ne pas utiliser dans les cuisines. • Le ventilateur ne doit pas être installé dans un plafond à isolation thermique supérieure a R-40.
  • Página 4: Raccordement Électrique

    montage. OUVERTURE DE DÉCHARGE C. Sortir le moteur et le mettre de côté pour plus tard. 2. Enlever une des débouchures de raccordement de boîtier. DÉBOUCHURE BOÎTIER MONTAGE DU BOÎTIER 1. Voir la Figure 3. Insérer les pattes de montage à chaque PATTE DE extrémité...
  • Página 5: Combinación Quiettest

    • No lo instale en un techo aislado en un valor mayor de R40. • Apropiado para utilizar con controles de la velocidad de estado sólido. Utilice TORNILLO el Modelo VS-64 de NuTone. VERDE • No lo utilice en cocinas.
  • Página 6 MONTAJE DE LA CAJA 1. Refiérase a la Figura 3. Inserte las consolas para el montaje ABERTURA DE DESCARGA en cada uno de los extremos de la caja. 2. Coloque el lado largo de la caja paralelo a la vigueta del techo. HACER Coloque la caja en la ubicación deseada.
  • Página 7 One Year Limited Warranty WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.