FEATURES AND CONTROLS

Control Panel

2
1
NOTICE Total power drawn from all receptacles must not exceed the Data Decal rating.
1. Engine Switch – Engine Switch – Flip the switch to the "ON"(l) position and pull the recoil starter to start
the generator. Turn to the "OFF"(O) position to turn off the generator.
2. 4-1 Data-Minder (Multi-Meter) – Push the SELECT button to show the Voltage, Hertz, running hours and
low oil alarm.
3. 120V, 30A Twist Lock – NEMA L5-30R
A maximum of 30 Amps current may be drawn from this receptacle.
4. 120V, 30A RV – NEMA TT-30R
A maximum of 30 Amps current may be drawn from this receptacle.
5. 120V, 20A Duplex - NEMA 5-20R (Not GFCI protected)
A maximum of 20 Amps current may be drawn from this duplex receptacle.
6. Ground Terminal – Consult an electrician or authority having jurisdiction for local grounding
requirements.
7. Circuit Breakers – The receptacles are protected by AC circuit protectors. If the generator is
overloaded or an external short circuit occurs, a circuit protector may trip. If tripping occurs,
disconnect all electrical loads and determine the cause before attempting to continue using the
generator. Reset any tripped circuit protectors.
If multiple receptacles are used at the same time, the total current must be kept with-in the
portable generator Data Decal rating.
8. Outlet Cover - Protects the receptacles from dust and debris.
English
3
4
7
09
8
5
6
Customer Service: 1-844-FIRMAN1