Beta 1467E Instrucciones página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Beta
ELECTRIC BRAKE FLUID REMOVAL TOOL
OPERATING AND MAINTENANCE MANUAL
INTRODUCTION
This is a practical, handy device for bleeding the
braking system of any motor vehicle.
The machine must be used only for that purpose.
Even the best machine can work well and be efficient
only if it is used correctly and kept in perfect working
order. Therefore, please read this instruction booklet
carefully and read it again whenever any problems
arise while using the machine.
NOTE: To adjust the device to technological progress
and specific production or installation requirements,
the manufacturer may decide to make changes to it
without notice. Hence, even if the illustrations
contained in this manual slightly differ from your
device, safety and information on it are guaranteed.
TECHNICAL DATA
Width
Length
Max. height
Power supply
Machine weight
MACHINE PREPARATION
CIRCUIT FILLING
(1)
When the machine is used for the first time, all the air
must be blown off from the circuit; to do so, take the
following steps:
– Connect the device to the power supply
– Make sure that the residual pressure exhaust valve
is closed
– Put the suction pipe into a vessel containing clean
brake fluid, using one of the adapting cone-shaped
caps supplied with the machine; make sure that the
pipe touches the bottom of the vessel.
– Fit one of the adapters available in the kit onto the
delivery pipe and keep it on a recovery vessel
INSTRUCTIONS
1467E
U/M
(2)
mm
400
– Turn the switch to ON; this will start the pump that
mm
320
mm
950
– The circuit will be completely free from air when
V/Hz
230/50
kg
13
(3)
– Fluid free from bubbles now comes out of the
– Open the residual pressure exhaust valve and keep
(1)
sucks up fluid from the vessel and conveys it
towards the delivery pipe, thus filling the fluid circuit
and expelling air
only clean fluid free from air bubbles comes out of
the delivery pipe
(2)
delivery pipe; immediately turn the switch to OFF
it open, until the pressure gauge on the machine
indicates 0; then close it back
GB

Publicidad

Tabla de contenido
loading

Tabla de contenido