FAULTS
5
The pump stops
after having run
for a short time.
12. GUARANTEE
Any modification made without prior authorisation relieves the manufacturer of all responsibility. All the
spare parts used in repairs must be authentic and all accessories must be authorised by the manufacturer,
in order to ensure maximum safety of the machines and of the systems in which they may be installed.
This product is covered by a legal guarantee (for 24 months from date of purchase) against all defects that can be assigned
to manufacturing faults or to the material used.
The product under guarantee may, at discretion, either be replaced with one in perfect working order or replaced free of
charge if the following conditions are observed:
the product has been used correctly in compliance with the instructions and not attempt has been made to repair
it by the buyer or by third parties.
the product has been consigned to the outlet where it was purchased, attaching a document as proof of purchase
(invoice or cash register receipt) and a brief description of the problem found.
The impeller and parts subject to wear are not covered by the guarantee. Intervention under guarantee does not extend
the initial guarantee period in any way.
CHECKS (possible causes)
A. The thermal overload protection device stops
the pump.
ENGLISH
A. Check that the fluid to be pumped is not
B. Check that the water temperature is not
C. Make sure there is no solid body
D. Power supply doesn't comply with the
5
REMEDIES
too dense as it would cause overheating
of the motor.
too high.
obstructing the impeller.
nameplate's data.