Descargar Imprimir esta página

Grohe Chiara 19 628 Manual De Instrucciones página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

952032.book : I95203US.FM Seite 1 Montag, Oktober 11, 1999 3:27 PM
Installation
Final installation
- Finish plaster wall and tile up to the fitting template. When doing
so, seal wall openings against water splashes.
• In the case of tiles laid in mortar, pointing must be bevelled
outwards.
• In the case of prefabricated walls, seal with elastic sealing
compounds.
- Remove fitting template (Y), see fig. [1].
Fit escutcheon with shut-off valve handle,
see figs. [1], [2] and [3].
1. Push sleeves (A and A1) with the mark (B) upward onto mixer
shanks, make sure that the marking point (B1) snaps into the
sleeve (A1), see fig. [1].
2. Fit escutcheon support (C) on the mixer, grease
O-rings (D and D1) with the grease provided and slide onto the
sleeves (A and A1), see fig. [2].
3. Place escutcheon (E) on the escutcheon support (C), hold in
position and secure with screws (F).
4. Snap trim frame (G) into escutcheon (E).
5. Push shut-off handle base (H) on, see fig [3].
6. Push on shut-off handle (I) and secure with the screw inside.
7. Push decorative sleeve (J) on the shut-off handle (I).
8. Fit the decorative ring complete (K) or lever complete and screw
on handle cap (L).
9. For assembly of the thermostat handle, see chapter
"Adjustment".
Reversed union (hot on right - cold on left).
Replace thermoelement (47 450), see replacement parts fold-out
page II, ref. No.: 47 282 (1/2").
If thermostat is installed too deep, the fitting depth can be
increased by 27,5mm (1 1/8") with extension set Part No. 47 461,
see fold-out page II.
If the thermostat is installed too shallow, the fitting depth can be
reduced by 12mm (1/2") with a spacer Part No. 47 464 , see fold-
out page II.
Adjustment
Temperature setting, see figs. [4] and [5].
• Before the mixer is put into service, if the mixed water
temperature measured at the point of discharge varies from the
specified temperature set on the termostat handle.
• After each service on the thermostat mixer.
1. Open shut-off valve (M) and measure the temperature of the
water emerging with a thermometer, see fig. [4].
2. Turn the green regulator nut (N) clockwise - counterclockwise
with a screwdriver until the water emerging has reached a
temperature of 100 °F (38 °C).
3. Fit the thermostat handle (P) so that the 100 °F (38 °C) mark on
the thermostat handle lines up with the mark (B) on the
sleeve (A1), see fig. [5].
4. Insert fixing ring (Q) and push decorative sleeve (R) on the
thermostat handle (P).
5. Push on decorative ring complete (S) or lever complete and
screw on handle cap (T).
Temperature limitation
When in proper calibration, the temperature range is limited to
110 °F (43 °C). There is a safety check at 100 °F (38 °C).
If a higher temperature is desired, one can exceed 100 °F (38 °C)
by overriding the safety check.
Prevention of frost damage
When the domestic water system is drained, the thermostat mixers
must be drained seperately, since check valves are installed in the
hot and cold water connections.
The complete thermostat assembly and check valves must be
unscrewed and removed.
1
English
Maintenance
For Maintenance, see figs. [6], [7] and fold-out page II.
I. Thermostat cartridge
1. Turn thermostat handle (47 427, 47 431) or lever thermostat
handle (47 432, 47 434) to the 100 °F (38 °C) safety check,
see fold-out page II.
2. Remove thermostat handle cap (47 428) and deco-rative ring
complete (47 429) or lever complete (47 433).
3. Take out fixing ring (Q).
4. Pull off thermostat handle (P).
5. Pull sleeve (A1) from the mixer shank by pressing down the
tongue (W), see fig. [6].
6. Extract clamp (U).
7. Pull stop ring (V) until resistance is encountered
(approximately 10mm [3/8"]), see fig. [7].
8. Unscrew stop ring (V) complete with regulator nut (N).
9. Remove shut-off handle cap (47 428) and decorative ring
complete (47 429) or lever complete (47 433), see fold-out
page II.
10.Remove escutcheon (47 443), see fig. [2] and installation on
page 1, Points 2 - 4, in reverse order.
11.Close both service stops (47 017).
12.Unscrew thermostat cartridge (47 450) with 24mm (15/16")
open-ended spanner.
Reassembly should be carried out in reverse order.
Temperature adjustment is necessary after each service of the
thermostat cartridge (see Adjustment).
II. Ceramic cartridge, see fold-out page II.
1. Remove shut-off handle cap (47 428) and deco-rative ring
complete (47 429) or lever complete (47 433).
2. Slacken internal screw of the shut-off handle (I) and pull it off.
3. Turn thermostat handle (47 427, 47 431) or lever thermostat
handle (47 432, 47 434) to the 100 °F (38 °C) safety check.
4. Remove thermostat handle cap (47 428) and decorative ring
complete (47 429) or lever complete (47 433).
5. Extract fixing ring (Q).
6. Pull off thermostat handle (P).
7. Remove escutcheon (47 443), see fig. [2] and installation on
page 1, Points 2 - 4, in reverse order.
8. Close both service stops (47 017).
9. Unscrew ceramic cartridge (45 888) with 17mm (11/16") open-
ended spanner.
Reassembly should be carried out in reverse order.
III. Check valve
1. Proceed as for Maintenance of ceramic cartridge, Points 1 - 8.
2. Unscrew check valve (14 116) with 17mm (11/16") socket
wrench.
Reassembly should be carried out in reverse order.
Check, clean and if necessary, replace parts.
Grease with special valve grease (Cat. No. 18 012)
Only original Grohe replacement parts may be
used !
Replacement parts, see fold-out page II (* = special accessories)
Care
Instructions for care of this thermostat mixer will be found in the
Limited Warranty supplement.

Publicidad

loading

Este manual también es adecuado para:

Chiara 19 629Chiara 19 630Chiara 19 631