Overview
The VTi
Celtic Vertical Motor contains two internal motors, one for traversing and the other for
®
vane tilting. Different configurations the dip switches, located on the side of the motor, dictates
whether you are adjusting the traversing or the tilting limits. To adjust the motor limits it is
necessary to use the VTi
Make sure the wall switch is properly installed
TILTING MOTOR
PUSH BUTTONS TO
SET THE TILTING LIMITS
STOP
BUTTON
vertilux.com
2
© 2019. Vertilux, Ltd. All Rights Reserved. Last revised: February 2019.
Celtic Radio Receiver & Transformer Wall Switch (6-700-AT-AC227).
®
PUSH BUTTONS TO
SET THE TRAVERSING LIMITS
L: Line
100-240 V AC
E: Ground
Input Voltage
N: Neutral
100-240 V AC
DIRECTION
BUTTONS
WALL CONTROL
(6 700 AT AC227)
FRONT
Fig.
1. Wiring Connection Scheme
(fig.
1).
TRAVERSING MOTOR
24 V DC
Output Voltage
WALL CONTROL
(6 700 AT AC227)
TRACK
ELECTRICAL
CONNECTOR
1
2 3 4
DIP
ON
DIP SWITCHES
BACK