Descargar Imprimir esta página

Led Brightness - Victron energy Skylla-i Control GX Manual

Ocultar thumbs Ver también para Skylla-i Control GX:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1.1 Turning the charger on and off
The Skylla-i charger is switched on and off by briefly pressing the on|off button. Note that the main
power switch on the charger is dominant, once it is switched off on the charger, the panel cannot
switch the charger on anymore.
1.2 Setting the charger input current limit
The input current limit is modified by briefly pressing and releasing the rotary knob. The selection
will automatically jump to input current limit if it was not yet active. Next the display shows the
actual input current limit and blinks. Turn the rotary now to modify the input current limit. To
confirm the new value either wait several seconds or briefly press and release the rotary knob.

1.3 LED brightness

For your comfort, the brightness of the LEDs is controlled automatically using a light sensor.
When the ambient light level becomes lower the LEDs will be less bright which is more pleasant
for the eye and reduces power consumption.
1.4 Multiple Skylla-i's and Control panels in one VE.Can network
The Skylla-i control panel can only be connected to one Skylla-i charger. Paralleling multiple
Skylla-i chargers and controlling them with one Skylla-i control panel is not possible. To connect
more pairs of Skylla-i's and control panels in one VE.Can network, the NMEA2000 device
instance numbers is used to distinguish the pairs.
A Skylla-i panel controls the Skylla-i charger with the same device instance. The default device
instance is zero. It is not necessary to configure anything for an out of the box installation, with
one Skylla-i and one control panel.
To change the device instance, use a NMEA2000 network tool from for example Actisense or
Maretron.
To manually reset the device instance in the Skylla-i control panel to zero, press and hold the
pushbutton on the back for four seconds. After the four seconds the panel will restart (all LEDs will
temporary light up), and the device instance is to zero.
2

Publicidad

loading