DEEP WELL PUMP INSTALLATION
(4" DIAMETER CASED WELL)
For wells over 25, but not exceeding 80 feet in depth, the
twin ejector must be installed down inside the well rather
than attached to the front of the pump. Materials with part
numbers are quality Water Ace parts.
General Materials
• One Jet Tank System #R-520C-T7. Includes: 1/2 HP jet pump
mounted on a 7-gallon diaphragm pressure tank, pressure
gauge # RG-2, and twin ejector with gasket, bolts, venturi
tubes, and foot valve
• One can PVC cement (read instructions carefully)
• One can thread compound (read instructions carefully)
• One 1-1/4" close nipple
• One 1" x 4" nipple
REMINDER: ALL JOINTS AND CONNECTIONS MUST BE AIRTIGHT. A SINGLE PINHOLE LEAK
WILL PREVENT THE PROPER OPERATION OF THE PUMP. USE THREAD COMPOUND ON ALL
THREADED CONNECTIONS UNLESS SPECIFIED OTHERWISE.
Thread 1-1/4" close nipple
STEP
into foot valve. Thread the
1
other end of 1-1/4" close
nipple into bottom of twin
ejector. Hand tighten, then tighten 1/4
turn with pipe wrench.
The ejector has two holes
STEP
in the top of it. Thread
2
deep well venturi tube (part
#25881A328 stamped on
the side) into larger hole until snug.
Thread 1" x 5" nipple into smaller hole.
Only hand tighten venturi tube. Tighten
nipple 1/4 turn with pipe wrench.
Thread a 1-1/4" male PVC
STEP
adapter over the venturi
3
tube and into ejector. Thread
a 1" female PVC adapter onto
1" x 5" nipple. Tighten adapters 1/4 turn
with crescent wrench.
Subtract five feet from the
STEP
depth of your well. This is
4
the total length of PVC pipe
and couplings to cement onto
both the 1-1/4" male and 1" female PVC
adapters. Cement a section of PVC pipe
to each adapter.
23833A203
• Two 1" female PVC adapters
• One 1" male PVC adapter
• Two 1-1/4" male PVC adapters
• Enough rigid 1-1/4" PVC pipe and couplings to reach from
bottom of well to pump (delivery pipe)
• Enough rigid 1" PVC pipe and couplings to reach from bottom
of well to pump (pressure pipe)
• One well seal #RWS4-1012
• One 1-1/4" PVC elbow
• One 1" PVC elbow
• One 1" x 5" nipple
STEP
5
EJECTOR
1-1/4"
into well. Cement as many couplings
CLOSE
NIPPLE
and sections of rigid PVC pipe on both
sides of ejector as it takes to equal the
FOOT
VALVE
depth of your well minus five feet,
then firmly clamp assembly with a pipe
clamp to prevent it from sliding down
into the well.
1" X 5"
NIPPLE
VENTURI
TUBE
EJECTOR
1" FEMALE
PVC
1-1/4" MALE
ADAPTER
PVC
ADAPTER
STEP
6
assembly slide down into well. Position
assembly so that twelve inches of PVC
pipes protrude from well seal. Using
1"
PVC
1-1/4"
crescent wrench, turn bolts on well seal
PIPE
PVC
PIPE
counterclockwise until rubber gaskets
are tight against the well casing and
the PVC pipes.
6
Lower the assembly into
the well, foot valve first.
Use a pipe clamp to prevent
assembly for sliding down
Remove pipe clamp and
slide well seal #RWS4-1012
over PVC pipes and onto
well casing. DO NOT let
12" OF
PVC PIPE
PROTRUD-
ING FROM
WELL
SEAL
WELL SEAL