I. SAFETY NOTICES
ATTENTION!
- WARNING: NEVER touch any of the electrical components directly when equipment
is removed from package.
- The serial interface RS-485 can not be used simultaneously with the serial
interface RS-232 .
II. GENERAL INFORMATION
This guide provides information for the correct installation, configuration and
operation of
EBE Board in the CFW-09
III. PACKAGE CONTENT
- 1 Expansion Board packaged in anti-static plastic sheets.
NOTE!
- Check if the model indicated on the package label matches the ordered ones.
- Remove the Expansion board from the anti-static plastic package carefully.
- Hold the board only on the sides. Do not touch directly on the components.

1. EBE BOARD INSTALLATION

The EBE board is installed on the CC9 control board, secured by spacers and
connected via terminal blocks (connectors) XC11 (which supplies the expansion board with
24V) and XC3.
For installing the board, follow the guidelines bellow:
Step 1
With the frequency inverter not energized, remove the CFW-09 frontal cover;
Step 2
If the inverter is Size 1, remove also the lateral cover;
Step 3
Carefully insert terminal block XC3 into the female connector XC3 on the CC9
control board;
Step 4
Check if all pins of the XC3 connector are connected correctly;
Step 5
Press on the EBE board center (near XC3) and on the left top edge until complete
insertion of the connector and plastic spacer;
Step 6
Secure the board to the 2 metallic spacers with the 2 screws provided;
Step 7
Plug the XC11 cable connector of the expansion board to the XC11 connector of
the control board CC9.
EBE EXPANSION BOARD
.