Descargar Imprimir esta página

NA-DE 10820 Manual De Instrucciones página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

TS EN 60669-2-1
TS EN 60598-2-1
Complies with ROHS Regulation Directive
2002/95/EC
10820-10830-10840-10850
e-MOTION CEILING TYPE LED SENSORLIGHT WITH 180°
MOTION SENSOR
USAGE AREAS
• At the building entrances, stair vestibules.
• At the long halls within the flats.
• At the places required within the flats.
• At the parking garage.
• At the requisite locations within the hotels.
• At the schools, hospitals and oil filing station.
"OFFERS ENERGY SAVING FEATURE''
GENERAL SECURITY CAUTIONS
• Take off the original package and control if there is any damage of transportation
and general view of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply any liquid.
• Protect from any stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist
electricians must install and apply.
CAUTIONS FOR INSTALLATION AND USAGE
• Installing must be carried out professionally in accordance with applicable national
wiring and electrical operating conditions.
• Turn of the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Fix the bulb before operating.
• Use 6A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 10 - 15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting
of the time and daylight.
• After you determine the right setting of the daylight, you can arrange the time as you
need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And
that you can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the glass, take of carefully and clean with a dry rag.
• Avoid mounting the detector close to objects that can cause rapid temperature changes
such as heaters, fans, refrigerators and ovents etc, and prevent the detector from
point-blank sunshine.
• It can cause the device operate inaccurately if there is tree, brushes etc. in the
coverage area.
SPECIFICATIONS
Operating voltage
Angle of coverage
Mounting Height
Detection Range
Time setting
Protection class
Opr. temperature
The amount of light emitted
Emergency lighting
Emergency lighting duration
Battery
Power consumption (Active/Stand-by)
Detection range is determined at the temperature of +20°C
SETTING
TIME
LUX
SENSE
(LUX) Daylight setting
The sensor's response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob anti-clockwise device will operate at dark.
Control dial set clockwise
= daylight operation approx. 2000 lux.
Control dial set anti clockwise = night-time operation approx. 2 lux.
(TIME) (f) Time setting
Light ON time can be adjusted continuously from
"10 sec. ± 1 sec. / 5 min. ± 10 sec." If you turn the knob anti-clockwise device
will operate at minimum time. (10 seconds)
Control dial set to anticlockwise = Shortest time (10 sec. ± 1 sec.)
Control dial set to clockwise= Longest time (5 min. ± 10 sec.)
(SENSE) Detection Range Setting
SENSE adjustment is used to set the detection range. For optimum range, please set the knob
to middle point. For maximum range (12 m) please turn clockwise, for minimum range (3 m) turn
anti-clockwise.
NOTE: Device will automatically make its own offset by checking environment for
approximately 5 minutes after the first installation. After this period device will operate
normally. If you think the device does not operate normal in first installation, please
wait for 5 minutes and start to test again. Be sure that there is no motion by this period.
10820-10830
10840-10850
230-240V~ 50/60 Hz
180°
2.2 m.
3-12 m.
10 sec. ± 1 sec. / 5 min. ± 10 sec.
IP43
CLASS 2
-20°C ~ +40°C
WW (3000K) 158 lm / CW (6500K) 165 lm
-
10840 = 12 lm
10850 = 22 lm
-
2 Hours
-
3x1.2V 1000mAh ni-mh AAA
4.8W / 0.7W
5.8W / 1.5W
DETECTING RANGE
SYSTEM COMPONENTS
(a) Body
(b) Wall mounting hole
(c) Terminals
(d) Led card
(e) plastic part of angle
(f) Cable hole
(g) Screw of fix to glass
(h) 10820 - 10840 glass
(›) 10830 - 10850 glass
Mounting figure a part to the wall surface by in figure b holes with screw as a parallel to wall.
Then make the L-N connections to the terminals which shows by figure c. After making the
setting according to the room condition, mount the plastic glass cover on the body carefully
with the glass screws as indicated at (h) and (›). Gently screws otherwise glass might be broken.
TROUBLESHOOTING
MALFUNCTION
• Led is off
• There is no
electricity on the
device
• Continuously
led is on
• Change
perception
area in device
DETECTION AREA :
Detection area of motion sensors depends on the angle between PIR detector and moving
direction, temperature (power of lamps changes this temperature), mounting style and mounting
place. Temperature is very important for operation for motion sensor like all electronic devices.
Using higher value of loads written on manuals and packages will decrease temprature inside
the device when using Na-De Ceiling Armatures with Motion Sensor. As a result detection range
will decrease and may cause defect of electronic components. Environment temperature will
also cause decrease of detection range. Detection range give is determined at +20°C. If the
weather is hot, it will decrease.
Walking targential to the sensor
(normal detection range)
The maximum detection range can be realized when walking tangential to the sensor (figure1)
When walking directly to the sensor detection range will be low. Because you will not be able
to cut vertical areas. Detection range of 10820, 10830, 10840 and 10850 models is 12 m.
GUARANTY
We will remedy defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement at our own discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded. Claims under the warranty will only be
accepted if the unit is sent fully assembled and well packed complete with a brief description
of the fault, a receipt or invoice ( date of purchase and dealer's stamp) to the appropriate
Service Center.
info@na-de.com.tr • www.na-de.com.tr
(L) = Line conductor
(N) = Neutral conductor
( ) = Protective earth conductor
Connect line (L) and neutral (N) to the terminal block.
12 m.
12 m.
24 m.
(a)
(h)
(b)
(b)
(c)
(d)
(g)
(g)
(f)
(b)
(b)
(e)
CAUSE
• Daylight adjustment set to
• Control daylight setting and
night-time mode during daytime
re-adjust
operate
• Power switch off or no electricity
• Check the electricity and power on.
• Fuse faulty
• Change the fuse.
• Fuse switch off or fuse faulty
• Check the fuse if necessary use
a new fuse.
• Connection faulty.
• Check the connection cables.
• Continuously movement in
• Check the detection zone.
detection zone
• Cars on the streets are being
• Avert it is being detection.
detected.
• Wind, rain, snow is moving to the
• Change detection zone, change
trees & bushes or open windows in
site of installation.
detection zone.
• Sudden temperature changes due
• Change site of installation or
to weather(wind, rain, snow) or the
keep the reasons away.
air expelled from fans.
• Different ambient temperatures.
• Change site of installation.
Figure 1
Walking directly to the sensor
(lower detection range)
KK-10820/830/840/850_150409_TR_EN00
12 m.
(›)
SOLUTION

Publicidad

loading

Este manual también es adecuado para:

108301084010850