Monacor International PSS-600E Manual De Instrucciones página 2

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
Switch Mode Power Supply Unit
GB
Please read these operating instructions carefully prior to
operating the unit and keep them for later reference.
1 Applications
This power supply unit is used for direct current supply of
small units with an operating voltage between 3 V
12 V and a maximum current consumption of:
PSS-600E
600 mA
PSS-1000E 1000 mA (1 A)
PSS-1500E 1500 mA (1.5 A)
The output voltage is adjustable to 3 V, 4.5 V, 5 V, 6 V,
7.5 V, 9 V or 12 V. The unit is protected against short cir-
cuit, overload and overheating. The special feature of the
power supply unit is its extra low current consumption
(< 0.3 W) when the unit connected has been switched off.
2 Safety Notes
This unit corresponds to all required directives of the EU
and is therefore marked with
WARNING The unit uses dangerous mains voltage.
Leave servicing to skilled personnel only.
Inexpert handling unit may result in elec-
tric shock.
G
The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity and heat (admissible ambient temperature
range 0 – 40 °C).
G
Do not operate the unit or immediately disconnect the
plug from the mains socket
1. if the unit is visibly damaged,
2. if a defect might have occurred after the unit was
dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the unit must be repaired by skilled per-
sonnel.
G
For cleaning only use a dry, soft cloth; never use chem-
icals or water.
G
No guarantee claims for the unit and no liability for any
resulting personal damage or material damage will be
accepted if the unit is used for other purposes than
originally intended, if it is not correctly connected, if it is
overloaded or if it is not repaired in an expert way.
If the unit is to be put out of operation defini-
tively, take it to a local recycling plant for a dis-
posal which is not harmful to the environment.
Œ
Positive pole at the tip or at
the inner contact
PSS-600E
PSS-1000E
®
PSS-1500E
.

Negative pole at the tip or
at the inner contact
®
MONACOR INTERNATIONAL GmbH & Co. KG • Zum Falsch 36 • 28307 Bremen • Germany
Copyright
©
by MONACOR INTERNATIONAL. All rights reserved.
Order No. 27.3030
Order No. 27.3130
Order No. 27.3140
3 Operation
1) Determine the operating voltage of the unit to be sup-
plied with power (
of the unit) and adjust the voltage by turning the switch
(3) with the key supplied (2).
2) Select the matching adapter from the 7 adapters sup-
plied:
and
Type
Diameter (mm)
2.5
Plug
3.5
outside
2.35
3.5
Hollow
5.0
plug
5.5
5.5
3) Determine the position of the positive and negative
poles at the power supply jack of the unit to be con-
nected (
marking of the jack) and connect the
adapter to the inline jack (1) accordingly.
With this marking or a similar marking of the
power supply jack, the positive pole must be at
the tip or at the inner contact of the adapter:
Connect the adapter to the inline jack in such a
way that the arrow of the inline jack will point to
the number/numbers of the adapter (fig. 1).
With this marking, the negative pole must be at
the tip or at the inner contact of the adapter:
Connect the adapter to the inline jack in such a
way that the arrow of the inline jack will point to
the identification letter (fig. 2).
4) Use the correct adapter to connect the power supply
unit to the unit to be supplied with power; then connect
it to a mains socket (100 – 240 V~, 50 – 60 Hz). The red
power LED will light up.
4 Specifications
Power supply
Power consumption
Output voltage
Output current
Subject to technical modification.
1
marking of the power supply jack
Identification letter
A
B
inside
0.75
S
1.35
H
2.1
D
2.1
E
2.5
G
PSS-600E
PSS-1000E
100 – 240 V~, 50 – 60 Hz
20 VA max.
25 VA max.
in no-load operation < 0,3 W
3/4.5/5/6/7.5/9/12 V
600 mA max. 1 A max.
KEY
2
3
A-0943.99.04.05.2011
PSS-1500E
35 VA max.
1.5 A max.
PSS-600E
SWITCH MODE PSU
PRI:100 -240 V ˜ /50-60 Hz/20 VA
SEC:
3 4.5 5
6
7.5 9
12 V4
600 600 600 600 600 600 600 mA
6V
5V
7 .5V
4.5V
9V
3V
12V
Ž