Descargar Imprimir esta página

Monacor International PSS-1000USB Manual De Instrucciones página 2

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
Switch Mode Power Supply Unit
GB
Please read these operating instructions carefully prior to
operating the unit and keep them for later reference.
1 Applications
This power supply unit is used for direct current supply of
small units with an operating voltage between 3 V
12 V
and a maximum current consumption of 1 A. The
output voltage is adjustable to 3 V, 4.5 V, 5 V, 6 V, 7.5 V,
9 V or 12 V. The unit is protected against short circuit,
overload and overheating. The special feature of the
power supply unit is its extra low current consumption
(< 0.3 W) when the unit connected has been switched off.
2 Safety Notes
This unit corresponds to all relevant directives of the EU
and is therefore marked with
WARNING The unit uses dangerous mains voltage.
Leave servicing to skilled personnel only.
Inexpert handling of the unit may result in
electric shock.
G
The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity and heat (admissible ambient temperature
range 0 – 40 °C).
G
Do not operate the unit or immediately disconnect the
plug from the mains socket
1. if the unit is visibly damaged,
2. if a defect might have occurred after the unit was
dropped or suffered a similar accident,
3. if malfunctions occur.
In any case the unit must be repaired by skilled per-
sonnel.
G
For cleaning only use a dry, soft cloth; never use chem-
icals or water.
G
No guarantee claims for the unit and no liability for any
resulting personal damage or material damage will be
accepted if the unit is used for other purposes than
originally intended, if it is not correctly connected, if it is
overloaded or if it is not repaired in an expert way.
If the unit is to be put out of operation defini-
tively, take it to a local recycling plant for a dis-
posal which is not harmful to the environment.
PSS-1000USB
KEY
SWITCH MODE PSU
PRI:100 -240 V ˜ /50-60 Hz/250 mA
SEC:
3 4.5 5
6
7.5
9
12 V4
1
1
1
1
1
1
1
A
6V
5V
7 .5V
4.5V
9V
3V
12V
1
Œ
®
PSS-1000USB
.
2
3
®
MONACOR INTERNATIONAL GmbH & Co. KG • Zum Falsch 36 • 28307 Bremen • Germany
Copyright
©
by MONACOR INTERNATIONAL. All rights reserved.
Order No. 27.3330
3 Operation
1) Determine the operating voltage of the unit to be sup-
plied with power (
of the unit) and adjust the voltage by turning the switch
(1) with the key supplied (2).
CAUTION! When using the USB adapter, always set
the voltage to 5 V to prevent damage to the unit con-
and
nected.
2) Select the matching adapter from the 8 adapters sup-
plied:
Type
Diameter (mm)
USB
2.5
Plug
3.5
outside
2.35
3.5
Hollow
5.0
plug
5.5
5.5
3) When using a plug or hollow plug, determine the posi-
tion of the positive and negative poles at the power
supply jack of the unit to be connected (
the jack) and connect the adapter to the inline jack (3)
accordingly. It is only possible to connect the USB
adapter in such a way that the arrow of the inline jack
points to the symbol
With this marking or a similar marking of the
power supply jack, the positive pole must be at
the tip or at the inner contact of the adapter:
The arrow of the inline jack must point to the
number / numbers of the adapter (fig. 2).
With this marking, the negative pole must be at
the tip or at the inner contact of the adapter:
The arrow of the inline jack must point to the
identification letter (fig. 3).
4) Use the correct adapter to connect the power supply
unit to the unit to be supplied with power; then connect
it to a mains socket (100 – 240 V~, 50 – 60 Hz). The red
power LED will light up.
4 Specifications
Power supply: . . . . . . 100 – 240 V~/50 – 60 Hz/250 mA max.
Power consumption
in no-load operation: . < 0.3 W
Output voltage: . . . . . . 3/4.5/5/6/7.5/9/12 V
Output current: . . . . . . 1 A max.
Subject to technical modification.

Positive pole at the tip or
at the inner contact
marking of the power supply jack
Identification letter
FUSB1
A
B
inside
0.75
S
1.35
H
2.1
D
2.1
E
2.5
G
.
Ž
Negative pole at the tip or
at the inner contact
A-1219.99.02.03.2014
marking of

Publicidad

loading

Este manual también es adecuado para:

27.3330