Do not tamper with appliance components.
REFERENCE STANDARDS AND LAWS
Install the appliance in accordance with the safety
standards in force in the country.
UNPACKING
Check the state of the packing and in the event of
damage, ask the delivery person to inspect the
goods.
Remove the packing
Remove the protective film from the outer
panels.Use a suitable solvent to remove any
residual adhesive from the panels.
POSITIONING
The overall dimensions of the appliance and the
position of connections are given on the
installation diagram at the start of this manual.
The appliance is not suitable for integrated
installation.
Position the appliance at least 10 cm from
adjacent walls. This distance can be reduced in
the presence of non-combustible walls or heat-
insulated walls.
The appliance has no moving parts which could
affect the stability, therefore, are not provided for
locking elements to the ground.
CONNECTIONS
The position and dimensions of connections are
given in the installation diagram at the end of this
manual.
Connection to the water supply
The appliance must be connected to a potable
water supply (max 35°C.) . The water inlet
pressure must be between 1, 5 - 3 bar. Use a
pressure reducer if the inlet pressure is above the
maximum permitted level.
Install a mechanical filter and a shut-off valve
upstream of the appliance in an easily accessible
point.
It is necessary to have a supply of drinking water
with hardness<10 °F to avoid circuit blockage.
Make sure the water circuit is free of ferrous
particles before connecting the filter and the
appliance.
Seal any unused connectors with a plug.
Once the appliance has been installed, check for
gas leaks at the connection points.
Installation of a water softener is
recommended to avoid limestone
deposit.
Water discharge
Water discharge is located in the lower part of
the oven and is to be connected to a rigid pipe,
the diameter of which should fit the discharge
connection.
The down flow pipe must be fitted at least 20 cm,
underneath the attachment.
Any discharge blockage can be the cause of any
bad odours in the baking chamber or of any
steam coming out of the door.
ELECTRICAL CONNECTIONS
Check that the appliance is designed to operate at
the voltage and frequency of the power supply
present on site. Check the details given on the
appliance dataplate.
Install upstream of the equipment in an easily
accessible place, an all-pole disconnecting device
with a contact gap of allowing full disconnection
under the conditions of overvoltage category III.
A
flexible
rubber
specifications not lower than type H05 RN-F must
be used for connection.
Connect the power supply cable to the terminal
board as shown in the wiring diagram supplied
with the appliance.
Secure the power supply cable with the cable
clamp.
Protect the power supply cable on the outside of
the appliance with a rigid plastic or metal pipe.
PROTECTIVE EARTH AND EARTH BONDING
CONNECTIONS
12
cable
with
insulation

Publicidad