(FIG.1)
INSTALLATION (Fig.1)
1. Fasten mounting strap (B) to outlet box (A) with two 8-32
screws (C).
2. Thread hex nut (A.c) and washer (A.b) onto threaded tubing
(A.a).
3. Thread one end of threaded tubing (A.a) into loop (D).
4. Thread other end of threaded tube (A.a) into mounting strap
(B).
5. Slip canopy (E) over loop (D) and adjust height of loop so half of
the
threaded area on the loop is exposed. After loop height is
A.b
adjusted, tighten hex nut (A.c) and washer (A.b) up against
A.c
mounting strap, to lock threaded tubing in position.
6. Taking the chain, determine the length you require to hang the
fixture.
(FIG.2)
7. Attach one end of the chain (A.d) to the top loop of the fixture.
8. Now slip loop collar (F) and canopy (E) onto chain.
9. Attach other end of chain to loop (D). Request assistance for
this step since
fixture may be heavy and difficult to hold while attaching the
chain.
10. Unwrap supply wire and ground wire and weave them up
through the chain.
11. Slip supply wire and ground wire through center of loop (A.a).
12. Connect ground wire to mounting strap (B) using green
ground screw (F).
13. Connect positive supply wire (typically black or the smooth,
unmarked side of the two-conductor cord) to positive fixture lead
with appropriately sized twist on connector.
14. Connect negative supply wire (typically white or the ribbed,
marked side of the two-conductor cord) to negative fixture lead
with appropriately sized twist on connector.
15. After wires are connected, tuck them carefully inside outlet
box. Slip canopy up firmly against the ceiling and secure by
turning the threaded collar (F) on loop (D) until tight.