Descargar Imprimir esta página

Chronothermostat - Orbis LYRA Manual Del Usuario

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
MANUAL SWITCH
INDEX
24
12
PINS
SAVING
TEMPERATURE
SELECTOR
DESCRIPTION:
The chronothermostat LYRA is a friendly analog programmable room thermostat. It
is possible to set different temperatures at different periods of time.
Features
- 2 independent temperatures that can be programmed (Confort
Saving
).
- Daily programm
- Programming is very confortable as it can be done outside the base over a
dial with pins.
- Can be used to control heating or air condition.
- Minimum period between temperature levels: 15 minutes
Temperature range of adjustment:
Confort: +10 ºC to +40 ºC aprox.
Saving: 0 ºC to +25 ºC aprox.
- Manual override (Confort, automatic or Saving)
- Battery level test.
ATTENTION:
Electrical devices must be installed and assembled by authorized installer. Before
connecting, be sure that the conductors are not under voltage. The device is
internally protected against interference by a safety device.
INSTALLATION
Surface mounting or flush mounting. To fit the device, remove the fixing base by
pressing the push button of the lower part. Fix the base by using the attached
screws. To insert LYRA into the base, first introduce the two upper guides of the
base in the slots of the device and press on the lower part until the flange is fitted
in the apropiate existing hole.
CONNECTION
Connect according with the following schema:
AIR CONDITION
PLACING AND REPLACEMENT OF BATTERIES
The device is powered by two alkaline batteries LR06(AA) of 1,5 V (not included).
Observe the polarity indicated in the housing of batteries. The approximate
batteries duration is one year.
Please, put used batteries in appropriate batteries container.
The device incorporates a push button to test if the batteries still have good level. If
after pressing it, the LED indicator do not light, then replace the batteries.
LED
MANUAL SWITCH
ESFERA

Chronothermostat

CLOCK HANDS
CONFORT
TEMPERATURE
SELECTOR
1
2
3
HEATING
BATTERY TEST
PUSH-BUTTON
BATTERY COVER
CLOCK SETTING
Turn the dial clockwise so the index indicates the real time.
The hours handles shall also indicates the real time.
Lyra
PROGRAMMING
Move up all the pins. Move down the pins corresponding with the hours when the
temperature should be the confort one (
temperature (
MANUAL KNOB
3 positions.
.- Permanent in Confort temperature.
.- Automatic. According with the programing of the pins in the dial.
.- Permanent in Saving temperature.
TEMPERATURE ADJUSTMENT
Temperatures can be adjusted by using the selectors corresponding with Confort
(
) and Saving (
TECHNICAL FEATURES
and
Power supply:
Switching capacity:
Battery duration:
Action type:
Temperature accuracy:
Confort temperature range:
Saving temperature range:
Operating temperature:
Protection class:
Protection type:
Pollution situation:
DIMENSIONS:
) and the rest of the time the saving
) is selected.
) temperatures.
2 alkaline batteries LR06(AA) 1,5 V
5 (1) A 250 V∼
1 year roughly
1B, 1S, 1T and 1U
± 1 ºC
10 ºC to 40 ºC aprox.
0 ºC to 25 ºC aprox.
-10 ºC to 45 ºC
II according to EN 60335 when mounting as
intended.
IP 40 according to EN 60529
Normal
142
24
12
11.5
30
26
17
4
11
37.5
36
MOUNTING DIMENSIONS
ORBIS TECNOLOGIA ELECTRICA, S.A.
Lérida, 61
Teléfono: +34 91 5672277;
E-mail: info@ orbis.es
http://www.orbis.es
40
A016.73.56418
E-28020 MADRID
Fax: +34 91 5714006

Publicidad

loading