Cognex In-Sight 8000 Serie Manual De Instrucciones página 20

Ocultar thumbs Ver también para In-Sight 8000 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 120
8405 Vision System Specifications
Specifications
Power
Power Type
Power Consumption
Current
Voltage
1
Case Temperature
Storage Temperature
Humidity
Protection
Shock (Shipping and
Storage)
Vibration (Shipping and
Storage)
1
To verify case temperature, use the EV GetSystemConfig("Internal.Temperature") Extended Native Mode
command or GetSystemConfig("Internal.Temperature") spreadsheet function. When issued, it returns the vision
system's internal temperature in degrees Celsius, which is ±5 degrees above the vision system case temperature.
®
Refer to the In-Sight
Explorer Help file for more information.Additional cooling measures are required if the case
temperature cannot be kept below 50°C. Examples of such measures include: mounting the vision system to a heat
sink using the M3 mounting screws, reducing the ambient temperature and ensuring there is air flow over the vision
system.
Class 2 Power over Ethernet (PoE) device.
PoE Type A and Type B.
6.49 W maximum per Class 2 PoE.
Per Class 2 PoE requirements.
48VDC nominal, applied from a Class 2 PoE source, which is typically powered from
some other voltage.
0°C to 50°C (32°F to 122°F)
-20°C to 80°C (-4°F to 176°F)
< 80% non-condensing
IP30 with cables and lens attached.
IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z) axis) 80 Gs
2
(800m/s
at 11ms, half-sinusoidal)
IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to
2
500 Hz at 100m/s
/ 15mm)
8405
19

Publicidad

Tabla de contenido
loading

Tabla de contenido