Selezione funzioni
E
1 ON
Automatic Closing function activated; (1 OFF-deactivated);
2 ON
"Open Only" function with pushbutton (2-7) and remote control (AF - board inserted) activated;
2 OFF "Open-Close-Reverse" Function with pushbutton (2-7) and remote control (HF board inserted) activated;
3 ON
24V (10-E) output activated when moving and when closed;
3 OFF 24V (10-E) output activated when moving;
4 ON
"Steady action" function (remote control function disabled) activated;
5 ON
Pre-fl ashing activated during opening and closing;
6 ON
Obstacle presence detection activated; (6 OFF deactivated);
7 ON
"Slave" (motor-driven) function activated;(7 OFF deactivated)
8 OFF Immediate bar closing function activated; insert safety device to terminals 2-C5 (8 ON deactivated).
9 OFF "Total Stop" function (connect the pushbutton on 1-2) activated; (if not used select ON dipswitch);
10 ON Increased barrier braking action function activated;(10 OFF deactivated)
Adjustment of the speed of movement and delays
To regulate the speed of opening and closing, move the fast-on of the transformer
indicated with "A" on Min = minimum, Med. = Medium or Max. = maximum, while
for slowdowns, move the fast-on "B" to minimum or maximum.
E.g.: max. speed of opening and closing – max. slowdown (see drawing on the
right/left).