Warning
T
his uniT is inTended for professional use
r
ead all The insTrucTions in
This manual prior To use
• The 366 053 meter is an oval gear model pulse
transmitter. It is intended for installation in the
distribution line and connection to a monitoring
equipment.
• It is recommended that the flow rate measured
is placed approximately in the middle of the
operating range of the meter. Operation with
flow near the ends of the operating range may
cause a decrease in measurement accuracy.
• The equipment includes a LED indicator of valve
opening status (see section "Installation" for
proper configuration).
This equipment is designed to be installed directly in
distribution line pipe. The meter has a 1/2" BSP
connection at the inlet and outlet. It also includes an
inlet flange and a flange at the outlet. Avoid installing
the unit between rigid connections to prevent efforts
transmission of the pipeline.
It is recommended to install a pressure relief system
on the line to prevent damage from thermal
expansion.
To prevent damage from dirt or solid particles
carried by the fluid is recommended the installation
of a 200-mesh strainer at the meter inlet.
For connection to the monitoring equipment keep
2
836 875 R. 01/16
Samson Corporation • One Samson Way • N.C. 28778 Swannanoa USA • Phone (828) 686-8511 • Fax (828) 686-8533
Introduction
• Mounting, electrical installation, commissioning and
.
maintenance must be carried out by qualified staff.
• Only use the unit for the purposes for which it is
intended.
• This unit has not been approved for use in
commercial transactions.
• Do not alter or modify the unit.
• Do not exceed the maximum unit working
pressure. See page 4, technical specifications.
• Use the unit with fluids and solutions which are
compatible with the moist parts of the unit. See
the relevant section of the technical specifications.
• Observe the manufacturer's safety warnings for
the fluids used.
• The meter has been manufactured with low
tolerances in order to ensure high precision over
a wide range of flows and viscosity.
Installation
in mind that the meter generates
per gallon) for proper configuration.
Depending on the monitoring equipment units
system, shall be established the following settings:
Monitoring equipment units system
Configuration
Using fluids with high or low viscosity, as well as if
working with high flows or very low flows, calibration
may be required adjusting pulses per unit.
1211 ppg
American gallons
Litres
1211 ppg
320 ppl