Technical Specifications; Troubleshooting - Samson 366 053 Guía De Servicio Técnico Y Recambio

Contador de pulsos de pvc 1/2"
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Type
Moist part materials
Inlet connection
Outlet connection
Maximum working pressure
Compatible fluids
Flow
Viscosity range
Operating temperature
Precision
Pulse ratio
Maximum imput voltage
Weight
Dimensions
Symptom
The meter is inaccurate.
Reduced flow.
The meter does not count.
4
836 875 R. 01/16
Samson Corporation • One Samson Way • N.C. 28778 Swannanoa USA • Phone (828) 686-8511 • Fax (828) 686-8533

Technical Specifications

Oval gear meter.
Acetal, Stainless Steel, Viton, PVC.
1/2" BSP and flange.
1/2" BSP and flange.
435 psi (30 bar).
AUS 32 (DEF, AdBlue
windshield washer.
0.26 - 13 gpm (1 - 50 l/min)
(depending on the viscosity of the fluid and temperature).
1 to 2000 cSt.
14 ºF to 140 ºF (-10 ºC to 60 ºC).
±0.5%.
1211 ppg (320 ppl).
30 VDC.
1.1 lb (500 g).
3.6 in (93 mm)
Trouble-shooting
Possible cause
Erroneous calibration factor.
A fluid with very high or very low
viscosity is being used.
Very high or low fluid temperature.
The meter is working outside its
field of application (see technical
specifications).
Dirt in the measuring chamber.
Faulty reed sensor.
Loose connections.
Worn or damaged gears.
), glycol, coolant solutions, water,
®
Solution
Calibrate the meter.
Calibrate the meter.
Calibrate the meter.
Restore the working conditions
(flow, viscosity, temperature...) to
those required by the meter.
Clean the measuring chamber.
Inform technical support.
Check connections.
Disassemble the meter and clean
or replace gears.
2.64 in (67 mm)

Publicidad

Tabla de contenido
loading

Tabla de contenido