Installation
*Please refer to the Use & Care instruction booklet provided with this laundry center for further details.
WARNING - RISK OF FIRE
• Ensure the entire dryer exhaust system is clean and free of lint and debris prior to the
installation of your new laundry center. The entire exhaust system should be inspected and
cleaned a minimum of every 18 months with normal usage. Failure to comply with cleaning
your exhaust system will increase the RISK of FIRE.
• DO NOT install a clothes dryer with flexible plastic or flexible foil venting material. Flexible
venting materials are known to collapse, be easily crushed and trap lint. These conditions will
obstruct clothes dryer airflow and increase the risk of fire.
• DO NOT screen the exhaust ends of the vent system, or use any screws, rivets or other
fasteners that extend into the duct to assemble the exhaust system. NO screen or grate of
any mesh size is allowed to cover the outdoor exhaust opening.
• Install the laundry center according to the manufacturer's instructions and local codes.
• Laundry Center installation and service must be performed by a qualified installer, service
agency or the gas supplier.
• The electrical service to the dryer must conform with local codes and ordinances and the
latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, the Canadian
Electrical Code CSA C22.1 part 1.
• The gas service to the dryer must conform with local codes and ordinances and the latest
edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54, or in Canada, the Natural Gas
and Propane Installation Code, CSA B149.1. An individual manual shutoff valve must be
installed within 6 ft. (1.83 m) of the dryer in accordance with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54.
• The laundry center is designed under ANSI Z21.5.1/CSA 7.1 or UL 2158 - CAN/CSA C22.2
No. 112 (latest editions) for HOME USE only. This laundry center is not recommended for
commercial applications such as restaurants, beauty salons, etc.
• Destroy the carton and plastic bags after the laundry center is unpacked. Children might use
them to play. Cartons covered with rugs, bedspreads, or plastic sheets can become airtight
chambers causing suffocation. Place all materials in a garbage container or make materials
inaccessible to children.
The instructions in this manual and all other literature included with this dryer are not meant to
cover every possible condition and situation that may occur. Good safe practice and caution MUST
be applied when installing, operating and maintaining any appliance.
1
Installation Checklist
Shipping hardware
NO foil or plastic venting material
Approved vent hood exhausted to
Foam shipping restraint (inside wash tub)
removed and stored
outdoors
Foam shipping support (underneath
Gas supply (gas dryer)
appliance) removed and stored
Manual shutoff valve present in supply
Leveling
All connections sealed with approved
sealer and wrench tight
Laundry center is level, side-to-side and
front-to-back
Conversion kit for LP system
Cabinet is setting solid on all corners
Gas supply turned on
Water supply
No leaks present at all connections -
check with soapy water, NEVER check
Use only new hoses and verify rubber
with flame
sealing washers are installed
240V electric supply
HOT supply is connected to HOT inlet and
(electric dryer)
COLD supply is connected to COLD inlet
HOT and COLD water supply turned on
Approved NEMA 10-30R or 14-30R
service cord with all screws tight on
No leaks present at water supply
terminal block
connections or appliance inlet connections
-recheck in 24 hours
Approved strain relief installed
Drain
Terminal access cover installed before
initial operation
Stand pipe or wall drain height min. 33"
Electrical power
Drain hose secured in place with cable tie
(shipped in drum)
House power turned on
Exhaust venting
Laundry Center plugged in
Final checks
Free-flowing, clear of lint buildup
End of exhaust vent securely fastened
Installation Instructions and Use & Care
to exhaust port to prevent air leaks and
instruction read thoroughly
excess noise
Water enters drum when cycle starts with
4 inch (102 mm) rigid or semi-rigid
lid lowered and dryer door latches and
ducting of minimal length and turns
drum tumbles when cycle starts
Registration card sent in
For detailed information, refer to
the Use & Care instruction provided
with this laundry center.
For support in the U.S. call 1-877-4ELECTROLUX (1-877-435-3287) or visit www.electroluxappliances.com. For support in Canada call 1-800-265-8352 or visit www.electroluxappliances.ca.
for Frigidaire Laundry Center
*
2
Electrical requirements
Electric dryer
CIRCUIT - Individual 30 amp. branch circuit
fused with 30 amp. time delay fuses or circuit
breakers.
POWER SUPPLY - 3-wire or 4-wire, 240 volt,
single phase, 60 Hz, Alternating Current. The
power cord is NOT supplied with unit.
OUTLET RECEPTACLE - NEMA 10-30R or
NEMA 14-30R receptacle to be located so
the power supply cord is accessible when the
dryer is in the installed position.
GROUNDING CONNECTION - See "Grounding
requirements" in Use & Care instructions.
Gas dryer
CIRCUIT - Individual, properly polarized and
grounded 15 amp. branch circuit fused with
15 amp. time delay fuse or circuit breaker.
POWER SUPPLY - 2-wire, with ground, 120
volt, single phase, 60 Hz, Alternating Current.
POWER SUPPLY CORD - The dryer is equipped
with a 120 volt 3-wire power cord.
GROUNDING CONNECTION - See "Grounding
requirements" in Use & Care instructions.
WARNING
Improper connection of the equipment grounding conductor can cause an electrical shock that may
result in serious injury or death. Check with a licensed electrician if you are in doubt as to whether
the appliance is properly grounded.
3
Connect or Construct Vent Exhaust
•
Use only 4 inch rigid or
semi-rigid metal ducting
•
Clean lint from duct system
•
Use only metal foil tape to
connect ducts (no screws)
MAXIMUM LENGTH
of 4" (102 mm) Rigid Metal Duct
STANDARD VENT MODELS (Preferred)
VENT HOOD TYPE
4" (10.2 cm) louvered
0
56 ft. (17 m)
1
48 ft. (14.5 m)
2
40 ft. (12 m)
3
32 ft. (9.5 m)
DO NOT exceed 8 ft. (2.4m) total duct length if installing semi-rigid venting.
DO NOT install flexible plastic or flexible foil ducting material.
For detailed information, refer to the Use & Care instruction provided with
this laundry center.
4
Connect to Water Line and Drain
Connecting to the water line
1. Run some water from the hot and cold
faucets to flush the water lines and remove
1. The laundry center MUST be grounded. In
the event of malfunction or breakdown,
grounding will reduce the risk of electrical
shock by a path of least resistance for
electrical current.
2. Since your laundry center is equipped with
a power supply cord having an equipment-
grounding conductor and a grounding
plug, the plug MUST be plugged into
an appropriate, copper wired receptacle
that is properly installed and grounded
in accordance with all local codes and
ordinances or in the absence of local codes,
with the National Electrical Codes, ANSI/
NFPA 70 (latest edition), or in Canada, the
Canadian electrical code C22.1 part 1. If in
doubt, call a licensed electrician.
DO NOT cut off or alter the grounding prong
on the power supply cord. In situations
where a two-slot receptacle is present,
it is the owner's responsibility to have a
licensed electrician replace it with a properly
grounded three prong grounding type
receptacle.
ELECTRICAL SHOCK HAZARD
WARNING
FIRE HAZARD
•
Use 4" (10.2 cm) clamp to
connect dryer & exhaust
Never exceed more than
system
three-90˚ elbows in the exhaust
duct system.
•
Use 90° quick-turn elbow to
vent left or right from dryer
Correct
Correct
Incorrect
2.5" (6.35 cm)
Exhaust system must
42 ft. (13 m)
NO screen or grate
be vented outside with
of any mesh size is
34 ft. (10.5 m)
approved vent hood.
allowed to cover the
26 ft. (8 m)
exhaust opening.
18 ft. (5.5 m)
Incorrect
particles that might clog the water valve
screens and to determine which faucet is
hot and which is cold supply.
Leave these instructions with the customer.
TO INSTALLER:
2. Check to ensure that the inlet hoses have
another 2/3 turn with pliers. DO NOT bend,
the rubber washer firmly in place. Use only
kink, or pinch water inlet hoses.
new hoses.
5. Turn on the water and check for leaks.
3. Connect the HOT inlet hose to the HOT inlet
Connecting to the drain
connection on the washer and the COLD
1. Form a "U" shape on the end of the drain
inlet hose to the COLD inlet connection
hose with the hose pointed toward the
on the washer (cold on top). Tighten by
drain.
hand until snug. Then tighten each supply
connection another 2/3 turn with pliers.
2. Place the formed end in a laundry
DO NOT cross thread or over-tighten these
tub or a standpipe and secure the drain
connections.
hose with the cable tie (provided in the
enclosure package) to the standpipe, inlet
4. Connect the HOT inlet hose to the HOT
hose, laundry tub, etc. so the hose does
water supply and the COLD inlet hose to the
not pull out from the force of the water.
COLD water supply. Tighten by hand until
snug. Then tighten each supply connection
For detailed information, refer to
Use & Care instruction provided with
this laundry center.
5
Connect to Gas or Electric
Gas Dryer
Electric Dryer
1. Apply approved thread sealant.
2. Wrench-tighten gas line.
3. Turn on gas.
30 AMP
4. Open gas valve and check for leaks with
soapy water.
Don't Move
White Wire
Open
Close
Manual Shutoff
U.L.-Approved Strain Relief
WARNING
WARNING
ELECTRICAL SHOCK HAZARD
ELECTRICAL SHOCK HAZARD
DO NOT use an aluminum wired receptacle
A U.L. approved strain relief must be
with a copper wired power cord and plug
installed onto power cord. If the strain relief
(or vice versa). A chemical reaction occurs
is not attached, the cord can be pulled out of
between copper and aluminum and can
the dryer and can be cut by any movement
cause electrical shorts. The proper wiring and
of the cord, resulting in electrical shock.
receptacle is a copper wired power cord with a
copper wired receptacle.
WARNING
LP systems MUST use conversion kit installed by qualified technician. Improper gas installation
or LP conversion could result in injury or even death.
For detailed information, refer to the Use & Care instruction provided
with this laundry center.
6
Level and Connect
1. Use adjustable pliers to adjust the leveling legs so the laundry center is
level front-to-rear and side-to-side, and stable corner-to-corner
2. Connect power.
IMPORTANT
Please review "Troubleshooting" in your Use & Care instruction before calling for service.
For detailed information refer the Use & Care instruction provided with
this laundry center.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
30 AMP
Move
White Wire
White
Wire
Green
Wire
Black
or
Red
Wire
Install
A17468403 (2010)