Descargar Imprimir esta página

Mounting Instructions - Robin HEF-100 Manual De Instrucciones

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8

Mounting instructions

Technical characteristics
Maximum air flow: 90 m3/h
Motor protection IP44
Class II
Recommendations
The electrical connection and the installation of the extract fan should be made in accordance with the
laws enforced in each country.
For a correct electrical installation a single pole switch should be used with a gap of at least 3 mm.
between contacts.
In bathrooms, the unit must be installed in such a way that it is out of reach of a person in the shower or
bath. The switch must be installed outside the bathroom.
In case of high humidity, it is advisable to install the duct outlet horizontally with a slight downward
inclination to facilitate moisture run off.
Installation (Fig. 1)
1. The air discharge is provided either directly through a wall (a wall (a 106 mm. Ø hole should be
provided), or through a 100 mm. Ø duct. Also air discharge is possible through a common duct.
2. Remove the grille (1) by releasing the screw (2).
3. Place the gasket seal at the outlet of the unit (3).
4. Fix the unit (screws supplied in the packing) feeding the electrical cable from behind (4) or to the side
(7).
5. Check that the propeller turns freely.
6. Open the connection cover (8) and proceed to the appropriate electrical wiring depending on the HEF
model. Then close the connection cover.
7. Mount the grille (1) and screw (2) again.
Electrical connection (Fig. 2 to 8)
The HEF-100 units are class II (double insulation) and do not need an earth connection.
Connect according with the details provided for each type of fan.
In all cases, the fan can be connected by a separate switch or through the light switch.
Performance
... Units supplied with a removable shutter operated by a thermal actuator (30 second
HEF-100 P
average time required for the louver to be fully open).
Units equipped with a fixed non-adjustable timer.
HEF-100 T and PT
HEF-100 R and PR
time required (connection diagram Fig. 4):
- Clockwise: to increase run on time
- Anti-clockwise: to decrease run on time
On/Off switch unit
HEF-100 M
HEF-100 H and PH
RH (Relative Humidity). The hygrostat automatically switches the unit on when the relative humidity in
the room exceeds the preset value. To adjust the required humidity level, remove the grille (1) and turn
the potenciometer (H) Fig. 6. These units also have a pull cord switch to override the hygrostat when the
humidity level is lower than the preset value.
-
Automatic operation
(Fig. 6).
-
Manual and automatic operation
function (Fig. 7 pilot lamp on).
-
Use of the light switch
unit Fig. 8).
Units equipped with adjustable timer. Turn the potentiometer R to adjust the run on
Units equipped with an adjustable hygrostat which can be varied from 60% to 90%
: Pull cord switch open (pilot lamp off) and pull cord placed inside the unit
: Pull cord switch open (pilot lamp off and pull cord placed inside the
: Pull cord provided for manual override of the automatic

Publicidad

loading