Playback timed daily light cycle: ramp on, fixed during ignition ramp and off during off fixed.
An output with full cycle transition, dawn, day, dusk and night
An output with selectable operating: 20% of dusk / dawn 80% cycle.
The circuit supports strips of LEDs and incandescent bulbs 12 VDC. Not supported bulbs led type.
Install a fuse and a switch for the safety and security as reflected in the CE standard.
Lecture chronométré cycle de lumière quotidienne: la rampe sur, fixe pendant l'allumage rampe et se éteignent pendant off fixe.
Une sortie à la transition complète du cycle, aube, jour, crépuscule et la nuit
Une sortie à l'exploitation sélectionnable: 20% du crépuscule / l'aube cycle de 80%.
Le circuit prend en charge les bandes de LED et ampoules à incandescence 12 VDC. Ampoules non pris en charge type LED.
Installez un fusible et un interrupteur pour la sûreté et la sécurité comme en témoigne la norme CE.
Reproducción temporizada de un ciclo de luz diario: rampa de encendido, transcurso de encendido fijo, rampa de apagado y
transcurso de apagado fijo.
Una salida con la transición completa del ciclo, amanecer, día, anochecer y noche
Una salida con funcionamiento seleccionable : al 20% del anochecer / al 80% del ciclo amanecer.
El circuito admite tiras de leds y bombillas de incandescencia de 12 VCC. No admite bombillas de tipo led.
Instale un fusible y un interruptor para la protección y seguridad tal y como refleja la norma CE.
PROGRAMMING: Functions of DIP.
The DIP [Sw1] switch 1, determines the mode of operation of the output [Following].
The DIP [Sw1], switch 2 designates the time scale for knobs [Fix] and [Ramps].
PROGRAMMING: Functions of DIP.
The DIP [Sw1] switch 1, determines the mode of operation of the output [Following].
The DIP [Sw1], switch 2 designates the time scale for knobs [Fix] and [Ramps].
PROGRAMACIÓN : Funciones del DIP.
El DIP [Sw1], interruptor 1, determina el modo de funcionamiento de la Salida [Following].
El DIP [Sw1], interruptor 2, designa la escala de tiempos para los potenciómetros [Fix] y [Ramps].
www.cebek.com
-
sat@cebek.com
Day-Night Regulator
Régulateur Jour-Nuit
Regulador Dia-Noche
12VDC - 2 outputs
R-45
Technical characteristics
Power : 12 V DC.
Consumption : Min. / Max. 5 mA.
Maximum load per output: 12 V DC. / 4 A.
Outputs: full cycle. Output single day / night.
Check out full cycle: Dawn, day, dusk, night.
Departure day / night: Steady on 20/80% of the full cycle
Timing: 2 selectable scales: 1-120 sec. / 1 to 120 min.
Indicators: Power Led.
Net Weight: 126 gr.
Dimensions: 107 x 98 x 30 mm.
Rail-Din: C-7587.

Publicidad

loading

Resumen de contenidos para CEBEK R-45

  • Página 1 Day-Night Regulator Régulateur Jour-Nuit Regulador Dia-Noche 12VDC - 2 outputs R-45 Technical characteristics Power : 12 V DC. Consumption : Min. / Max. 5 mA. Maximum load per output: 12 V DC. / 4 A. Outputs: full cycle. Output single day / night.
  • Página 2 R-45 Programming Timing : Timing is assigned as one and the same parameter for the 2 outputs. The potentiometer [Fix] establishes the timing of transitions fixed on-off cycle. The potentiometer [Ramps] determines the timing of the ramps progressive and progressive on off cycle.
  • Página 3 R-45 INSTALLATION : Warning. I did not spend the CN2 connector for any connection, it may cause the malfunction of the circuit. Its use is reserved only for helpdesk functions. INSTALLATION : Attention. Je ne ai pas passé le connecteur CN2 pour toute connexion, il peut entraîner un dysfonctionnement du circuit. Son utilisation est réservée uniquement pour les fonctions de helpdesk.
  • Página 4 R-45 OPERATION : Duty Cycle. The two outputs work simultaneously and are activated or deactivated depending on the course of the cycle. Transitions always keep the same order, resulting in a cyclical fashion. See drawing. The cycle rate will depend on the timing assigned to the ramps on / off switch, potentiometer [Ramps], and the timing assigned to fixed courses of on / off switch, potentiometer [Fix].