AXIS A1001 Network Door Controller
1. READER I/O 1 & 2: Reader I/O connector (2x). DC output: 12 V DC, max 300 mA
2. RELAY & PWR*: Power & relay connector. DC output: 12 V DC, max 500 mA. Relay: 30
V DC, max 700 mA
3. LOCK*: Power lock connector. 2x 12 V DC. 0 V DC, floating, or 12 V DC, max total
load: 500 mA
4. DC IN: Power connector. DC input: 10–30 V DC, max 26 W. Max load on outputs: 14 W
5. AUX: Auxiliary connector. DC output: 3.3 V DC, max 100 mA. Digital input: 0 to max 40
V DC. Digital output: 0 to max 40 V DC, open drain, 100 mA
6. READER DATA 1 & 2: Reader data connector (2x). RS485 full duplex, RS485 half duplex,
Wiegand
7. DOOR IN 1 & 2: Door connector (2x). Digital input: 0 to max 40 V DC
8. Network connector. RJ45, PoE IEEE 802.3af/802.3at Type 1 Class 3. Max load on outputs:
7.5 W
*If the lock is non-polarized, we recommend you to add an external flyback diode.