2. Installing the Fan Coil
Wine Guardian split system fan coil units should be in-
stalled indoors inside the wine room. The fan coil unit can
be located either above, or below the condensing unit in
height Keep any height difference to a maximum of
15' (4.57meters).

Surface Mounting


Locate the wall studs using a stud finder and mark
locations. (Pic 1 & 2)

Mark the bracket mounting location on the wall and
secure the bracket to the wall studs. (Pic 3).
C. Mark a 1/4" and 5/16" hole in the wall where it is re-
quired to run the refrigerant lines and 1/2" hole for
the condensate drain.
D. Cut the holes in the wall and route the refrigerant line
-sets, condensate drain, and 24-volt control cable.

Hang fan coil from bracket.
Through-the-Wall Mounting

Locate the wall studs using a stud finder and mark
locations. (Pic 1 & 2)

Mark penetration dimensions on the wall for mount-
ing location, around 6ft off the ground is ideal (Pic
4).
C.
Cut a 14.5"W x 16.25" H hole and slide the
EasyMount™ sleeve through wall so that it is flush
with the wall surface (make sure the sleeve is level
and
square). (Pic 5)
D.
Screw sleeve into wall.

Slide unit through the Easy Mount sleeve and caulk
joint between unit and sleeve with silicone. Install
insulation strips around perimeter of sleeve.
2. Installing the Fan Coil Cont.
Fan-Coil Connections

Bend refrigerant tubing gently on back side of fan coil and
braze suction and liquid lines to interconnecting lines to the
condensing unit.

Connect the control wire to the 2-point, 24volt terminal strip.
C. Connect the condensate drain line to the drain at the back
of the unit. A one-inch drain trap is required for proper oper-
ation.
CAUTION: DRAIN LINE IS NOT INTERNALLY TRAPPED (a
1" deep trap is required for proper operation)
D. Plug in power cord to dedicated electrical receptacle
3