• LP dealer must purge tanks before filling.
• Dealer should NEVER fill LP tank more than 80% of LP tank
volume. Volume of propane in tanks will vary by temperature.
• A frosty regulator indicates gas overfill. Immediately close LP
tank valve and call local LP gas dealer for assistance.
• Do not release liquid propane (LP) gas into the atmosphere.
This is a hazardous practice.
• To remove gas from LP tank, contact an LP dealer or call a
local fire department for assistance. Check the telephone
directory under "Gas companies" for nearest certified LP
dealers.
LP Tank Exchange
• Many retailers that sell appliances offer you the option of
replacing your empty LP tanks through an exchange service.
Use only those reputable exchange companies that inspect,
precision fill, test and certify their cylinders. Exchange
your tank only for an OPD safety feature-equipped tank as
described in the "LP Tank" section of this manual.
• Always keep new and exchanged
LP tanks in upright position during use, transit or storage.
• Leak test new and exchanged LP tanks BEFORE connecting
to appliance.
LP Tank Leak Test For your Safety
• Leak test must be repeated each time LP tank is exchanged
or refilled.
• Do not smoke during leak test.
• Do not use an open flame to check for gas leaks.
Appliance must be leak checked outdoors in well-ventilated
area, away from ignition sources such as gas fired or
electrical appliances. During leak test, keep appliance away
from open flames or sparks.
Use a clean paintbrush and 50/50 soap and water solution. Use
mild soap and water. Do not use household cleaning agents.
Damage to gas train components can result. Brush soapy
solution onto all weld seams and entire valve area.
If "growing" bubbles appear, do not use or move the LP
tank. Contact an LP gas supplier or your fire department.
Page 6
WARNING
WARNING
• Do not use appliance until leak checked.
• If you cannot stop a gas leak, immediately close LP tank
valve and call LP gas supplier or your fire department!
Appliance must be leak checked outdoors in well-ventilated
area, away from ignition sources such as gas fired or
electrical appliances. During leak test, keep appliance away
from open flames or sparks.
Setup Using Optional Hose And Refillable Cylinder
1. Make sure burner valves are off.
2. Attach Camp Chef Model HRDSP hose to regulator and
regulator to stove (as shown).
3. Attach hose to cylinder.
4. Open cylinder valve.
5. Perform leak check on hose to regulator, and hose to cylinder
connections with soapy water. Bubbles indicate a leak. Check
that the connection is not cross-threaded and that it is tight.
Perform another leak check. If there is still a leak, remove
the cylinder and contact the manufacturer for service and
repair. 1-800-650-2433.
6. Turn off fuel at the cylinder and disconnect both ends of the
hose when not in use.
Dismantling Hose And Refillable Cylinder
1. Before dismantling the hose, be sure gas pressure in the
hose is eliminated.
2. Ignite stove and turn off gas valve on cylinder.
3. Allow flame to self-extinguish.
4. When flame is out, close valves on the appliance.
5. Remove hose.
Setup Instructions:
• Place stove on a flat, level, sturdy surface.
• Open the lid and attach the windscreens to the tabs on the
inside of the lid. Snap into place as shown.
• Grill Use: Ensure that the drip tray is in place.
WARNING
WARNING
Leak Check Regulator
& Hose