Other functions

Connecting cable device/cigarette
lighter
The supplied connecting cable has two functions:
Use the device as a data memory when
you change the battery of your vehicle.
Connect the Power Start with the connection ca-
ble to the vehicle s cigarette lighter before ou
remove the batter .
Note
In some vehicles, the ignition has to be
switched on to provide a current connec-
tion with the cigarette lighter.
Charge the Power Start via the ciga-
rette lighter.
Attention!
This function is only available for WPS 12-700
and WPS 12-900!
Connect the Power Start with the cigarette lighter.
Note
This function is especiall intended for
service vehicles that are in use often.
Indicator to determine the on-board
voltage (only for WPS 1224-700 and
WPS 12-700)
Set the operating switch [3] to the "0 position.
Connect the batter terminals [9] with the plus
and negative terminal of the vehicle batter .
The vehicle batter voltage is shown on the
3
displa [6].
When the displa ed value is larger than 15 V, then
an on-board voltage of 24 V is present.
When the value is smaller than 15V, checking the
on-board voltage according to the manufacturer
information is re uired.
18

Replacing the fuse

Risk of electric shock
Switch the device off before
¾
changing a fuse.
Disconnect the device from other
¾
devices.
Switch o the device using the operating
switch [3].
Disconnect the device from all other devices.
Let the fuse cool down completel (about 5 min-
utes).
To open the fuse holder [2] , remove the cover.
Loosen the two nuts and the bolts that attach the
fuse on the positive cable.
Remove the old fuse and insert a fuse of the same
t pe (see Technical Specifications).
Attach the fuse with the two nuts and bolts.
Attach the cover again on the fuse-holder.

Maintenance / care

Risk of fire or electric shock
Disconnect the device from the
¾
power suppl , prior to performing
maintenance or repair work.
The device must be constantl charged when
not in use.
The device can alwa s be connect to the charger
without being damaged.
Protect the device against humidit and moisture.
Clean the device onl b using a clean, dr cloth.
Store the device in an upright position in a cov-
ered, cool and dr place.
Check the unit before each use and ever
30 da s for damage.