CAUTION
Do not touch LEDs on fixture, care must be taken to not
come in contact with LED board(s) or connector(s) during
fixture installation.
5.
Align fixture without lens to four mount holes. For wall
mounted, note that the driver will be oriented at the
top as shown in (Figure 4). Tighten all four mounting
fasteners sufficiently to compress housing into gasket.
N
ote:
If mounting surface is uneven or rough, it will
be necessary to caulk around fixture to provide
water tight seal.
6.
Replace the lens by aligning (3) lens pins and mounting
plate slots. On the plate, they should be located at the
3, 9 and 12 O'clock positions. Use O-ring (Supplied)
with all four screws.
N
ote:
If using eyelid option, the lens should be
attached first using the shorter screws at the
"12 and 6 O'clock" position and fastened
securely. The eyelid should then be installed
with the longer screws at the "3 and 9 O'clock"
positions and fastened securely. If using Eyelid
option make sure the eyelid is also in the "UP"
position. (Figure 5) Do not over torque screws
during installation of lens.
Gasket
Back - Plate
Diagonal Mounting Holes
Figure 4. Flat Unit Installation
Figure 5. Eyelid (Downlight Installation)
COOPER LIGHTING SOLUTIONS
Installation Instructions - TR11 LED
Driver will
Clearance
always be on
Hole for
top
1/4" Bolt
Junction
Box
IB519021EN
Installation instructions
Wall
3