(B9).
- Remove the filter elements (B10).
Important!
Do not use abrasive cleaning agents or petrol
to clean the elements.
- Clean the elements by tapping them on a
flat surface. In cases of stubborn dirt first
clean with soapy water, and then rinse with
clear water and air dry.
- Assemble in reverse order.
8.3. Spark plug (B4)
Check the spark plug (item 17) for dirt and
grime after 50 hours of operation and if
necessary clean with a copper wire brush.
Thereafter service the spark plug after every
50 hours of operation.
- Pull off the spark plug boot with a twist.
- Remove the spark plug with the supplied
spark plug wrench (15).
- Assemble in reverse order.
8.4 Changing the oil and checking the oil level
(B7-8)
The motor oil is best changed when the
Engine is at working temperature.
- Only use motor oil SAE - 15W40 / (<0
[SAE - 5W30].
8.4.1 Fill up Oil. (B7)
- Open the oil filler plug by screw it off (9).
- Add exactly 0.6L engine oil with an oil filling
jug.
Or refer to content in 8.4.2.
- Screw the Oil filler plug back.
8.4.2 Checking Oil level. (B8)
- Place the generator on a slightly inclined
surface so that the dip stick is at proper
position.
- Screw off the Oil Filler plug and wipe off
any oil on the dip stick.
- Put the oil dip stick back without screw into
the Oil filler.
Important!
Do not screw the dipstick in to check the oil
level; simply insert it up to the thread.
- Check the dip stick; make sure the oil level
is between "H" and "L" mark.
8.4.3 Let out used Oil (B13)
- Open the oil filler screw (9) and connect the
drain pipe and oil jug (13).
- Drain the used oil into a suitable receptacle
by tilting the generator.
8.4.4 Changing Engine Oil
- changing engine oil refers to the content in
8.4.3 and 8.4.1.
8.5 Oil shortage cut-out
This generator has a Low Oil level Protection
system.
O
C)
The oil shortage cut-out responds if there is
too little oil in the engine. In this case it will
not be possible to start the engine or it will
cut out automatically after a short period
of time. It cannot be started again until the
engine oil has been topped up (see point
8.4.1).
8.6 Storage
If the generator is going to stop used for long
time (more than 3 months).
11