Installing LP Gas Tank
To operate, you will need one precision-filled standard grill LP gas
tank with external valve threads.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this
oven & grill.
W Caution: Always place your oven & grill on a
hard, non-combustible, level surface. An asphalt
or blacktop surface may not be acceptable for
this purpose.
W Caution: Move gas hoses as far away as possible from hot surfaces
and dripping hot grease.
W Caution: The gas hose should be arranged so that it will not be pulled
on or tripped over.
Inserting and Securing LP Gas Tank in Cart
Note: Cart is sold separately.
Loosen LP gas tank retainer bolt by turning counter-clockwise.
Place precision-filled LP gas tank upright into hole in cart body so the tank valve is facing the
gas line connection.
Secure tank by turning LP gas tank retainer bolt clockwise until tight.
Using as a portable grill
W WARNING: The cylinder
shall be placed 18 inches
minimum away from
appliance. Hose may cause
tip hazard.
Connecting LP Gas Tank
1.
Before connecting, be sure there is no debris caught
in the head of the LP gas tank, head of the regulator
valve or in the head of the burner or burner ports.
2.
Control knob must be in the " OFF" position
(Figure 2).
3.
Connect regulator/hose assembly to tank by turning
knob clockwise until it stops.
Disconnecting LP Gas Tank
1.
Before disconnecting, make sure the LP gas tank valve
is "CLOSED."
2.
Disconnect regulator/hose assembly from LP gas tank
by turning knob counterclockwise until it is loose.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to
moving this oven & grill.
3.
Place the protective cap cover on the LP tank and
store the tank outdoors in a well ventilated area out of
direct sunlight.
Operating Instructions
Checking for Leaks
20 lb
Burner Connections
9 Kg
1.
Make sure the regulator hose and valve
connections are securely fastened to the burner
and the tank.
12.2 in. / 31 cm
2.
Visually check the connection between the burner/
venturi tube and orifice.
3.
Make sure the burner/venturi tube fits over the
orifice.
W WARNING: Failure to inspect this
connection or follow these instructions
could cause a fire or an explosion
which can cause death, serious bodily
injury or damage to property.
4.
Please refer to diagram for proper installation
(Figure 1).
5.
If the burner/venturi tube does not rest flush to the
orifice, as shown, please contact 1.800.762.1142
for assistance.
Tank/Gas Line Connection
1.
Make 2-3 oz. of leak detection solution by mixing
one part liquid dishwashing soap with three parts
water.
2.
Make sure control knobs are in the " OFF"
position (Figure 2).
3.
Connect LP gas tank per "Installing LP Gas Tank"
section.
4.
Turn LP gas tank valve to "OPEN."
5.
Spoon several drops of solution, or use a squirt
bottle, at all "X" locations (Figures 1, 3 and 4).
a. If any bubbles appear, turn LP gas tank valve to
b. If you continue to see bubbles after several
c. If no bubbles appear after one minute, turn LP
First Use
Min. / Min.:
1.
Make sure all labels, packaging and protective
18 in. / plug.
films have been removed from the grill.
46 cm
2.
Remove manufacturing oils before cooking on
this grill for the first time by operating the grill
for at least 15 minutes on (HIGH) with the lid
closed. This will "heat clean" the internal parts and
dissipate odors.
Lighting
W CAUTION: Keep outdoor gas cooking
appliance area clear and free from
combustible materials, gasoline and
other flammable vapors and liquids.
W CAUTION: Do NOT obstruct the flow of
combustion and ventilation air.
W CAUTION: Check and clean burner/
venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
W CAUTION: Attempting to light the
burner with the lid closed may cause
an explosion.
W Caution: Always place your oven &
grill on a hard, non-combustible, level surface. An asphalt or blacktop
surface may not be acceptable for this purpose.
W Caution: Move gas hoses as far away as possible from hot surfaces
and dripping hot grease.
W Caution: The gas hose should be arranged so that it will not be pulled
on or tripped over.
1.
Open lid.
2.
Check for obstructions of airflow to the burners. Spiders, insects and webs can clog the
burner/venturi tube. A clogged burner tube can lead to a fire.
3.
Control knob must be in the " OFF" position (Figure 2).
4.
Connect LP gas tank per "Installing LP Gas Tank" section.
5.
Turn LP gas tank valve to "OPEN."
Outdoor LP Gas Pizza Oven & Grill
Model No. GOC1509MR
"CLOSED," reconnect and re-test.
attempts, turn LP gas tank valve to "CLOSED"
and disconnect LP gas tank, per "Disconnecting
LP Gas Tank" section. Contact 1.800.762.1142
for assistance.
gas tank valve to "CLOSED," wipe away solution
and proceed.
Figure 1
Burner/
Venturi
Tube
LP Gas
Connection
LP Gas
Valve with
Orifice
Figure 2
OFF
APAGADO
Figure 3
X
X
X
X
X
Figure 4
Figure 5
Match