PNEUMATIC CONNECTIONS
Install a 3/8 air treatment unit with a central connection for dry air upstream of the
unit, connecting it with two air hoses, Ø 6 x 14 (15) for dry air and 10 x 19 (14)
for lubricated air.
Now connect the two hoses protruding from the connection tube as follows:
- connect the Ø 10 x 19 hose to the hose connection Ø 12 (14), which supplies
the two couplings for pneumatic tools;
- connect the Ø 6 x 14 hose to the hose connection Ø 7 (15), which supplies the
utility air coupling.
Both hoses must be fastened in position using the clamps provided.
Refer to the pneumatic diagram provided with this manual illustrating connections
specific to each model.
START-UP
Minimum power supply requisites and connections:
Electric mains
- Single phase 110/230 V line with a ground wire of adequate section;
- a 16 A 6Ka - 30 mA differential magnetothermal switch should be installed
upstream of the power outlet.
Compressed air mains
- Maximum operating pressure: 8 bar;
- must supply adequately filtered dehumidified air.
OPERATING INSTRUCTIONS
Electrical tool connections
- Insert the tool's plug into the socket on the terminal;
- if the tool is equipped with a vacuum device, connect it using the sleeve;
- do not connect tools with loads over their rated capacity (3600 W max) to the
electrical sockets.
Pneumatic tool connections
- Connect the compressed air hose to the rapid fitting on the terminal; connect the
other end to the tool;
- if the tool is equipped with a vacuum device, connect it using the sleeve
(optional).
Preliminary checks
- Check that the dust bag is in the container and that the filter is assembled on the
head;
- check that the vacuum hose is properly fixed and does not hinder tool move-
ment;
- check that there are not leaks from the compressed air supply system.
Only after having performed connections should you proceed with a brief operating
trial of the tools following their instructions.

TROUBLESHOOTING

EFFECTS
The unit does not start up the suction system
The suction system does not
start up automatically
Insufficient suction capacity
No compressed air supply
to rapid couplings
When the pressure control is adjusted,
there is no change shown on the
pressure gauge
When both pneumatic tools
are connected the power level drops
USE OF MULTIFUNCTION TERMINAL
Manual operations
The machine operates in manual mode: turn the switch (6) to start the dust
vacuum turbine.
Automatic operations (PE1A - PE2A)
The terminals are equipped with sensors for automatic operating: the turbine auto-
matically starts when the electric or pneumatic tool is turned on. When finished,
turn the tool off and the turbine will stop automatically after 1 minute.
MAINTENANCE
The manufacturer or an authorised representative must carry out a technical ope-
rating inspection of the machine controls and check for any damage to the machi-
ne's filtering system at least once a year. RUPES Spa is not liable for any direct
or indirect damages due to failure to comply with the instructions provided in this
manual.
ORDINARY MAINTENANCE (to be performed by the user)
- inspect compressed air supply hoses and connections;
- inspect dust suction hoses.
EXTRAORDINARY MAINTENANCE (to be performed by the service centre)
- Periodically inspect the electric wires and plugs. If they are faulty or worn, replace
them;
- periodically inspect the compressed air hoses and connections.
GUARANTEE
All tools manufactured by RUPESSpa are guaranteed for 12 months from the
date of purchase against fabrication and material defects.
All tools must be used only with RUPES original accessories and spare parts:
we refuse all responsibility for damages or accidents caused by non-observance
of this rule which will also cause the termination of the guarantee.
The guarantee will no longer be valid if the instructions contained in this booklet are
not followed, if the tool is used for purposes other than that for which it is intended,
if it is dismantled, interfered with in any way or damaged due to neglect.
The guarantee will be made valid by filling-in the form on the inside back cover
of this instruction booklet.
If the tool is found to be defective or malfunctions, it should be returned carriage
free in one piece in its original packing together with the guarantee certificate to
the manufacturer or to one of the Assistance Centres listed in the appendix to this
booklet.
The guarantee does not automatically imply replacement of the tool.
RUPES Spa reserves the right to make any technical or design modification to
its products without prior notice.
The manufacturer is not liable for any print errors. This document voids and repla-
ces previous ones.
CAUSE
Power off
Faulty power supply cable or commutator
Faulty electronic module
or micro-switch
Suction system - Dust bag is overfull
There is an obstruction in one
of the hoses or accessories
Compressed air supply is not connected properly
Faulty control, or leakage from
compressed air supply
Insufficient air flow
SOLUTION
Check electrical connection
Contact authorised service centre
Contact authorised service centre
Empty the dust bag
Inspect the hose and the accessories
Inspect connection
Contact authorised service centre
Inspect airways