Installation
Installation
C
D
E
F
G
H
1.
Close the hot and cold water inlet.
2.
Remove the rubber plug (C) at the back of the lever.
3.
Loosen the setscrew (D) located on the side of the lever.
4.
rear lever
5.
Remove the lever (E).
6.
Remove the housing (F) (not threaded).
7.
Loosen the threaded ring (G).
8.
Remove the cartridge (H).
The cartridge seals (H1) must fit snugly into their housings on the single-lever body.
H
1