08) With the system on, adjust the volume level using the potentiometer. A good starting point is to set the
potentiometer half way (12 hours).
XLR Connectors:
PIN 3
NEGATIVE
Power Connector:
Search for standards practices, and legal requirements for your region before installing the system. The emergency
plug must comply with these legal requirements. Never stop doing this consultation, it is very important ensure compliance with
this rules;
The ac plug is not included and must be purchased by the contracted installer;
The assembly specification is shown in the figure above. (cylindrical PP cable 3x1,5mm²).
The plug should be 10A/250V;
The VL 18-SUB does not have the parallel connection configuration for the power cord;
Caution: whenever you install your equipment make sure that the voltage selected on the equipment conforms to the voltage of
your mains. Damage caused by faults of this type is not covered under warranty.
01) Set the volume potentiometer to the minimum;
02) Before plugging the VL18-SUB into the outlet, make sure
that the voltage of the VL18-SUB and the power supply are the
same.
03) Confirm that the ON / OFF button is in the OFF position;
04) Connect the XLR cable (Signal cable);
05) Connect the AC power cord supplied with the product to the
POWER connector on the rear panel of the amplifier;
06) Connect the power cord into a power outlet.
07) Turn on the power switch. The POWER LED on the rear
panel of the amplifier will light up.
PIN 2
PLUG XLR FEMALE
POSITIVE
BALANCED
PIN 1
GROUND
GROUND
PIN 2
POSITIVE
PIN 3
NEGATIVE
BROWN
PHASE
BLUE
GROUND
NEUTRAL
CONNECTION SETTING
PLUG XLR MALE
BALANCED
PIN 1
PIN 1
GROUND
PIN 3
NEGATIVE
O The power cord included with the product VL18-
SUB do not have the ac plug;
Its responsibility of the installer the mounting of the
GREEN
plug in the power cord;
This mounting must be made only by a qualified
technician, because only a professional can perform a perfect
installation;
17
STARTING UP
PIN 2
POSITIVE
PIN 3
NEGATIVE
PIN 1
GROUND
PIN 2
POSITIVE