Programming must be done while the control unit is powered off the mains, through the transformer. Programming
is not possible by using the buffer batteries only. This ensures that all times and functions of the control unit are
correctly programmed.
Programming of work times, deceleration and electronic clutch is executed in self-learning. At this stage, leaf move-
ment is at slow speed. Procedure:
1) Release the automated system , take it to about midway through opening travel, and then lock it.
2) Power up the control unit (power ON is signalled by the POWER LED).
3) Turn switch S2 to PROG: the flashing lamp goes on at steady light to signal programming.
4) Press the push-button connected to the START terminals or the remote-control, if data has been stored. The first
operation the automated system performs must be CLOSING.
5) If the application moves to open, to stop the movement of the automated system you must jumper-connect the
RESET pins by means of the relative connector (Fig. 02). When movement is stopped, position the connector in the
normal position again (Fig. 02).
6) Cut power to the control unit, reverse polarity of the two cables powering the motor, and repeat the operation
at point 1.
7) After the START command is given, the automated system
moves to close, until it reaches the closing stop or limit-switch
if supplied.
8) After about two seconds, the automated system restarts
opening automatically until it reaches the opening stops or
limit-switch if supplied.
9) The control unit begins counting pause time. After the required
time has elapsed, press the START command again, and the
automated system will close completely.
10) Programming is now finished. Turn switch S2 back to OFF – the
flashing lamp goes off.
FUSE
F1=T10A250V – 5x20
Closing
photocells
Opening
photocells
COM2
FTO
STOP
FTC
START
CLOSE
SP/LC
LAMP
COM1
FCC
FCA
Courtesy light
Flasher
Warning-light/
Courtesy light
7. PROGRAMMING
8. FUSES
SAFETY DEVICE
Motor /Power supply
9. OPERATIONAL DIAGRAM
Radio receiver
Connector for
radio receiver
FTO
STP
FTC
STA
CLOSE
Dip-switch
11
NORMAL
FUSE
F2=F3.15/250V – 5x20
Logic/ Accessories output
APM
CHM
-24
+24
-BAT
+BAT
VAC
VAC
transformer
RESET
Fig. 02
SAFETY DEVICE
230/115 V~
50/60 Hz
Toroidal